爱游戏平台注册登录
check quantity

AlphaLISA Anti-O-linked GlcNAc Acceptor Beads, 250 ug

AlphaLISA® Acceptor beads conjugated to an antibody against O-linked n-acetylglucosamine (O-linked GlcNAc). These beads can be used for AlphaLISA no-wash assays.

For research use only; not for diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption & disposal requirements under European REACH regulations (EC 1907/2006).

貨號
產品尺寸
AL144C
250 µg
更多
AL144M
5 mg
更多
AL144R
25 mg
更多
Request Technical Support

請輸入有效數量

請登錄以添加收藏夾。

購物車為空

詳細信息

AlphaLISA® Acceptor beads designed to detect O-linked n-acetylglucosamine (O-linked GlcNAc) in a homogeneous AlphaLISA assay. Broad species cross-reactivity is expected based on sequence similarity. Source of antibody: monoclonal.

The anti-O-linked GlcNAc AlphaLISA Acceptor beads were used for the development and optimization of an O-GlcNAc hydrolase (OGA) assay using a biotinylated Tau-derived peptide O-GlcNAcylated at Ser400 as substrate. A technical notes describing the assay is available in our product literature.

Features:

  • No-wash assay
  • Easy-to-automate
  • Fast assay optimization

AlphaScreen® and AlphaLISA® are bead-based assay technologies used to study biomolecular interactions in a microplate format. The acronym "Alpha" stands for amplified luminescent proximity homogeneous assay. As the name implies, some of the key features of these technologies are that they are non-radioactive, homogeneous proximity assays. Binding of molecules captured on the beads leads to an energy transfer from one bead to the other, ultimately producing a luminescent/fluorescent signal. To understand how a signal is produced, one must begin with an understanding of the beads. AlphaScreen and AlphaLISA assays require two bead types: Donor beads and Acceptor beads. Each bead type contains a different proprietary mixture of chemicals, which are key elements of the AlphaScreen technology. Donor beads contain a photosensitizer, phthalocyanine, which converts ambient oxygen to an excited and reactive form of O2, singlet oxygen, upon illumination at 680 nm. Please note that singlet oxygen is not a radical; it is molecular oxygen with a single excited electron. Like other excited molecules, singlet oxygen has a limited lifetime prior to falling back to ground state. Within its 4 µsec half-life, singlet oxygen can diffuse approximately 200 nm in solution. If an Acceptor bead is within that proximity, energy is transferred from the singlet oxygen to thioxene derivatives within the Acceptor bead, subsequently culminating in light production at 520-620 nm (AlphaScreen) or at 615 nm (AlphaLISA). In the absence of an Acceptor bead, singlet oxygen falls to ground state and no signal is produced. This proximity-dependent chemical energy transfer is the basis for AlphaScreen's homogeneous nature.

規格

抗體偶聯物 Anti-O-GlcNAc
自動化兼容 Yes
珠型或核心珠型 AlphaLISA Acceptor
檢測方法 Alpha
實驗類型 In vitro
Format Microplates
分子修飾 Glycosidation
產品品牌名稱 AlphaLISA
運輸條件 藍冰
產品尺寸 250 µg
資源
  • 所有

產品手冊

技術說明

AlphaLISA Tau-Ser400 O-GlcNAc hydrolase (OGA) Assay

AlphaLISA technology is a powerful and versatile platform that offers highly sensitive, no-wash immunoassays using Alpha Donor and AlphaLISA Acceptor beads. In this technical note, we present,the optimization of an OGA signal-decrease assay using as substrate a biotinylated Tau-derived peptide O-Glc ...

PDF 650 KB
Baidu
map