爱游戏平台注册登录 ’s NexION® 2000 is the most versatile ICP-MS on the market, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of an instrument that makes it easy to handle any sample matrix, any interference, and any particle size.

爱游戏平台注册登录 received on April 11, 2018 the Application Award from LaborPraxis in the category Bio and Pharma Analysis for the NexION 2000 ICP-MS. We were awarded this prize during analytica 2018 in Munich, Germany, in acknowledgment of a new technique enabling users to quantify the amount of metal in an individual cell for the first time.

Part Number
Model Name
N8150044
NexION 2000B
more
N8150045
NexION 2000C
more
N8150046
NexION 2000P
more
N8150047
NexION 2000S
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Ideal for testing and high-throughput laboratories, the NexION 2000P ICP-MS features:

  • A dedicated SMARTintro High Throughput/High Matrix sample-introduction module with a FAST valve and integrated All Matrix Solution delivers faster sample uptake and washout as well as the ability to handle high dissolved solids
  • Extended Dynamic Range capabilities provide the ability to detect high-and low-level elements in a single sample run
  • Three quadrupoles, three gas channels, and three modes of operation combine to offer better interference removal, delivering better detection limits/improved data accuracy
  • The industry’s fastest data acquisition speed on the market (100,000 points/sec) to handle any particle size
  • A new solid-state RF generator with revolutionary LumiCoil technology – first ICP-MS RF coil that requires no maintenance or cooling
  • Triple Cone Interface with Quadrupole Ion Deflector, delivering no maintenance beyond the cones
  • Syngistix software provides an intuitive interface that mirrors your workflow, with left-to-right, icon-based navigation that guides you through your analysis. Plus, it’s a cross-platform solution, easing the transition from technique to technique

The NexION 2000 ICP-MS – Triple Quad Power Meets Single Quad Versatility.

Specifications

21 CFR Part 11 Compatible Yes
Depth 69.0 cm
Height 75.0 cm
Model Name NexION 2000P
Portable No
Product Brand Name NexION
Warranty 1 Year
Weight 150.0 kg
Width 81.0 cm
Resources, Events & More
  • All

Application Brief

Arsenic Speciation Analysis in Rice Following Method GB 5009.11-2014 to Ensure Safety

Rice represents a dietary staple for over half of the world's population. However, in recent years, concerns have been raised over the presence of high levels of arsenic (As), where this carcinogenic metalloid can be accumulated at levels far exceeding ambient concentrations. Since China is the w ...

PDF 1 MB
PM10 and PM2.5 Air Pollution Monitoring and Source Apportionment in Asia Using the NexION ICP-MS

Concern about air pollution has been growing rapidly, with most of the focus on gaseous pollutants. Airborne particulates, especially small ones, are rapidly gaining attention due to their impact on human health, as smaller particles can be carried over long distances by wind and penetrate deep i ...

PDF 1 MB

Application Note

A Single Cell-ICP-MS Method to Study the Treatment Efficiency of Algaecide for Toxic Algal Bloom Control

Toxic cyanobacterial blooms were reported worldwide in various aquatic systems, including freshwater rivers, lakes, reservoirs, and eutrophied coastal marine habitats. Cyanobacterial blooms might be caused by a combination of multiple factors, including eutrophication, solar radiation, temperatur ...

PDF 2 MB
Accurate Sizing and Counting of 10 nm Gold Nanoparticles with the NexION ICP-MS

In this work, we demonstrate that 爱游戏平台注册登录 's NexION® 2000 ICP-MS, with its unique RF generator and ion optics, coupled with the Syngistix™ Nano Application Software Module, can be used to accurately measure and characterize NP sizes of 10 nm and smaller, both alone and in a mixture of NPs of vari ...

PDF 2 MB
Analysis of Cerium Dioxide Nanoparticles in Soil Using Single Particle ICP-MS

This work demonstrates a robust method using SP-ICP-MS technology to detect CeO2 NPs which were extracted from soil samples with tetrasodium pyrophosphate (TSPP). Over the past few decades, engineered nanoparticles (ENPs) have been increasingly used in many commercial products. As a result, more and ...

PDF 1 MB
Analysis of Major and Trace Elements in Plant-Based Foods Using the NexION ICP-MS

Plant-based foods using ingredients derived from fruits, nuts, vegetables, grains, and legumes, have gained increased attention for a variety of reasons, including but not limited to nutritional, environmental, sustainability, and ethical issues. While they have many benefits, they also present c ...

PDF 1 MB
Analysis of NIST Gold Nanoparticle Reference Materials Using the NexION Single Particle ICP-MS

To better understand the impact of nanoparticles, several key characteristics need to be assessed, such as concentration, composition, particle size, shape and other surface characteristics. The NexION® SP-ICP-MS, with Syngistix Nano Application software module, c ...

PDF 1 MB
Analysis of Rare Earth Elements by Laser Ablation-ICP-MS with the NexION 2000 ICP-MS

With the increasing development of high-tech applications, rare earth elements (REEs) are considered key elements for modern and future industries. Globally, there is growing pressure for analytical solutions that can accurately characterize and quantify REE content in a high-throughput manner to ...

PDF 1 MB
Analysis of SiO2 Nanoparticles in Standard Mode with Single Particle ICP-MS

With the development of nanotechnology and the increased use of nanoparticles (NPs) in numerous products and processes, the need to characterize them has also grown. Nanoparticles come in a wide variety of compositions, with silica dioxide (SiO2) nanoparticles being used in many areas. ...

PDF 1 MB
Analysis of Single-Walled Carbon Nanotubes with SP-ICP-MS

Measuring the amount of metals in CNTs presents a challenge. High levels can be measured directly in the solid by several techniques, including XRF and TEM, while low-level analysis requires complete digestion of the sample prior to analysis by ICP-OES or ICP-MS.

PDF 555 KB
Analysis of Soils and Waters Following U.S. EPA Method 6020B using the NexION 2000 ICP-MS

Through the years, both industry and analytical instrumentation have advanced. With the development of new chemicals and processes, new pollutants may enter the environment. However, the capabilities of analytical instruments have also increased, allowing the measurement of ever lower levels of envi ...

PDF 2 MB
Boron Isotope Ratio Analysis Using the NexION ICP-MS

Boron (B) is studied for its isotope ratio composition in a range of paleoproxy, geochemical, nuclear, medical, and archeological applications. ICP-MS is recognized as a powerful technique for boron isotope analysis. Quadrupole ICP-MS is versatile and not exclusively dedicated to isotope ratio me ...

PDF 3 MB
Characterization of TiO2 Nanoparticle Release from Fabrics By Single Particle ICP-MS

In the textile industry, the use of titanium dioxide (TiO2) nanoparticles (NPs) is increasing due to their ability to provide UV protection, increase the hydrophilic nature of fabrics, provide antibacterial characteristics, and reduce odors. This work demonstrates the ability of Perkin ...

PDF 516 KB
Determination of Impurities in Lithium Materials with the NexION 2000 ICP-MS

With growing concern about the state of the environment, more and more devices are being powered by lithium batteries due to their higher capacities, longer lives, and ability to be recycled, in comparison to conventional batteries. As with all consumer goods, safety and performance are critical ...

PDF 1 MB
Determination of Methyl and Inorganic Mercury in Fish with the NexSAR HPLC-ICP-MS Speciation Solution

Consumption of seafood is the primary exposure route of methylmercury for humans, emphasizing the importance of accurately measuring methylmercury in fish. As with all analytical method setup, the determination of methylmercury content in fish has to meet the criteria of modern analytical methodo ...

PDF 1 MB
Determination of Selenium Species in Drinking Water by HPLC-ICP-MS

Selenium (Se) is an essential element at trace levels, toxic at higher levels, and exists in several oxidation states in a variety of inorganic and organic compounds. Consequently, the chemistry of selenium is complex in both the environment and biota.

For the determination of selenium spec ...

PDF 907 KB
Determination of Toxic Elements in Food Following AOAC Method 2015.01 using the NexION ICP-MS

Concentrations of toxic elements in foods are present at trace to ultra-trace levels, requiring sensitive and reliable analytical techniques for accurate measurement. ICP-MS is a powerful technique with multi-element detection capabilities, low detection limits, high speed of analysis, and wide l ...

PDF 1 MB
Determination of Toxic and Other Trace Elements in Baby Foods Using the NexION ICP-MS

For many children around the globe, commercial baby foods are the main source of nutrients and energy, and therefore their quality and safety are critical and must be monitored. In March 2021, the U.S. House of Representatives introduced the “Baby Food Safety Act of 2021” to regulate the presence ...

PDF 699 KB
Determination of Trace Elements in Eye Drops with the NexION ICP-MS

Eye drops are commonly used medications which are available both over-the-counter and as prescriptions in various forms. Because eye drops are classified as a parenteral medication and have relatively large daily doses, the inorganic components in eye drops must be present at low concentrations. ...

PDF 475 KB
Direct Analysis of Trace Elements in Coastal Seawater Using the NexION 2000 ICP-MS

With rising global populations and the increasing industrialization of both land and sea, the contamination of coastal seawater by metals and metalloids is of increasing concern. This has an adverse effect on both the biological communities which live within these waters as well as the population ...

PDF 672 KB
Extraction of Gold Nanoparticles from Fish Larvae and Soils

Gold nanoparticles (AuNPs) are widely used in industrial and medical applications. They are known to form naturally during the weathering of Au-bearing mineral deposits, as well as the transformation of gold nuggets and particles. In freshwater systems, they bioaccumulate in aquatic organisms, as ...

PDF 1 MB
Improved Analysis of Fluid Inclusions with LA-ICP-MS Using the NexION ICP-MS: Advantages of a Fast-Scanning Quadrupole

The elemental concentration of fluid inclusions in geological samples provides information about geological processes that lead to the formation of ores and minerals. Laser ablation-ICP-MS (LA-ICP-MS) is the preferred technique for measuring elemental concentrations in fluid inclusions due to its ...

PDF 1 MB
Iron Nanoparticles by SP-ICP-MS: Overcoming Spectral Interferences Using Universal Cell Technology

With the increasing interest in nanoparticles (NPs), various ways of detecting and measuring them are being used. One of the most promising techniques for analyzing metallic NPs is single particle ICP-MS (SP-ICP-MS). This work demonstrates the ability of the NexION® SP-ICP-MS with Univ ...

PDF 1 MB
Measurement of Titanium Dioxide Nanoparticles in Sunscreen using Single Particle ICP-MS

Titanium dioxide (TiO2) nanoparticles are commonly used in sunscreens as part of the formulation to block the sun’s harmful UV rays. As the use of nanoparticles (NPs) in consumer products has increased, concern has risen as to the health and environmental effects of nanoparticles. Sinc ...

PDF 1 MB
Monitoring the Fate of Silver Nanoparticles in Seawater Using Single Particle ICP-MS

Single Particle (SP) ICP-MS is an analytical technique that has demonstrated tremendous potential for the measurement and characterization of metal-containing nanoparticles (NPs) in a wide range of sample types, including environmental. One of the most challenging matrices is seawater due to its ...

PDF 1 MB
Multi-Elemental Analysis of Soils Using the NexION ICP-MS

The elemental analysis of soils is of vital importance not only for agriculture, but also from an environmental perspective. Toxic metals enter soil primarily through pollution and can be taken up directly by humans in various manners, potentially causing acute or chronically toxic responses. The ...

PDF 1 MB
New Research Evaluating Cisplatin Uptake in Ovarian Cancer Cells by Single Cell ICP-MS

Cisplatin, carboplatin, and oxaliplatin are the most widely used of platinum-based cancer chemotherapy drugs in the Western world. Cisplatin's effectiveness is due to its ability to bind to the DNA, resulting in DNA-platinum (Pt) adducts, which bend the DNA. The cells must then repair the DNA damage ...

PDF 2 MB
NexION 2000: A Perfect Tool for the Determination of Trace Elements in Blood and Serum

This work demonstrates the ability of 爱游戏平台注册登录 's NexION 2000 ICP-MS to perform accurate, stable analyses of blood and serum samples, leveraging the benefits of the Universal Cell and the ability to use three cell gases in a single method.

PDF 931 KB
Quantification of Low Levels of Hexavalent Chromium in Water Using a NexSAR HPLC-ICP-MS

Due to rising concerns over the carcinogenic properties of hexavalent chromium (Cr6+) in drinking water, many national and regional water standards are looking to lower the maximum allowable levels of total chromium and hexavalent chromium in potable waters. And in order to assess trac ...

PDF 1 MB
Testing and Validation of Various Antacids for Elemental Impurities using the NexION 2000 ICP-MS

The United States Pharmacopeia (USP) has announced that its new standards for elemental impurities in drug products has been implemented since January 1, 2018. General Chapters <232> and <2232> specify the list of elements and their permissible daily exposure (PDE) limits based on the route of admin ...

PDF 576 KB

Brochure

A Complete Portfolio of Grain Testing Solutions

Grains, whether consumed whole or processed, have nutritional and functional requirements and must be safe for consumption, and the only way to ensure grain quality is through rigorous testing. That’s where 爱游戏平台注册登录 come in. Our easy-to-operate, integrated testing and analytical solutions enco ...

PDF 1 MB
Cannabis Testing Solutions Brochure

Whether your lab is well established or just starting up, having a single-source partner who can offer turnkey solutions that meet the current regulations is essential to a successful business. For years, we’ve worked with government and contract cannabis laboratories to develop industry-leading ...

PDF 9 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, ...

PDF 3 MB
Comprehensive and Compliant Solutions for Glass Analysis

It’s clear, glass has a variety of uses, from practical to technological to decorative. In particular, float glass is widely used in architecture, automotive, transportation, photovoltaic, and solar industries.

For glass testing labs around the world, we offer highly accurate and tailored ...

PDF 2 MB
Grain Testing Solutions Brochure

The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics.

爱游戏平台注册登录 is equipped to help the gr ...

PDF 6 MB
Refinery and Natural Gas Analysis Brochure

Oil refineries and natural gas producers around the world require their lab operations to perform large numbers of analyses before their products are used in industries and by consumers. Detection of even the slightest impurities, accurate process control and hydrocarbon distribution analysis is cri ...

PDF 5 MB
USP <232>/<233> & ICH Q3D Capabilities Brochure

The International Conference on Harmonization Guideline for Elemental Impurities Q3D (ICH Q3D) has established maximum permitted daily exposure limits for elemental impurities in pharmaceutical products. In combination with the U.S. Pharmacopeia’s (USP) Chapters <232> and <233> on elemental impur ...

PDF 3 MB

Catalog

Atomic Spectroscopy Consumables Catalog

Download your complete PDF catalog containing all the consumables needed to keep your Atomic Absorption, ICP-OES, and ICP-MS instruments up and running.

PDF 8 MB

Flyer

S20 Series Autosamplers

The S20 series is the next generation of high-performance, robust, and agile autosamplers designed specifically for 爱游戏平台注册登录 ’s spectroscopy platforms - atomic and molecular. The series is comprised of two autosamplers: the S23 with three racks and the S25 with five racks. They are designed to ...

PDF 1 MB
Supporting Sustainability with the NexION ICP-MS Series

Today’s sustainable solutions are opening exciting new ways for businesses to fuel economic growth, while minimizing adverse impact on people and the planet. Laboratories are also working sustainability into their business plans to reduce downtime, waste, and costs – and in many cases, improve th ...

PDF 1 MB

Guide

Atomic Spectroscopy - A Guide to Selecting the Appropriate Technique and System

Atomic spectroscopy is a family of techniques for determining the elemental composition of an analyte by its electromagnetic or mass spectrum. Several analytical techniques are available:

  • Atomic absorption (AA): flame and graphite furnace
  • Inductively coupled plasma optical emis ...

PDF 1 MB
NexION 1000/2000 ICP-MS Preparing Your Laboratory

爱游戏平台注册登录 ICP-MS instruments are complete systems with the exception of the following items which must be provided by the customer: electrical power, exhaust vents, argon gas supplies with approved regulator, cell gas supply with approved regulators

PDF 1 MB
NexION 1000/2000/5000 ICP-MS Consumables & Supplies Guide

Look to 爱游戏平台注册登录 for all of your consumables and supplies for your NexION 1000, 2000, or 5000 ICP-MS system.

PDF 3 MB

Poster

Infographic - Solutions for your Toxicology Lab

Infographic Poster showing the range of different analytical solutions for Toxicology Labs; from GC and LC, to ICP-MS and UV-Vis. Benchtop and floor standing chromatography, spectroscopy and thermal solutions for everyday robust and reliable analyses.

FOR RESEARCH USE ONLY. NOT FOR USE IN D ...

PDF 460 KB

Product Note

High Throughput System for ICP-MS and ICP-OES Product Note

Our High Throughput System (HTS) is a uniquely designed modular sample introduction that integrates with the NexION® series of ICP-MS and the Avio® series of ICP-OES to dramatically reduce sample-to-sample time, thereby improving sample throughput while maintaining o ...

PDF 1 MB

Technical Note

All Matrix Solution System for NexION ICP-MS Platforms

爱游戏平台注册登录 ’s AMS system provides a number of benefits to simplify analysis of high-matrix samples with theNexION family of ICP-MS instruments. By introducing a flow of argon into the spray chamber neck, the aerosol stream is diluted,allowing for more efficient ionization, fewer matrix effects, a ...

PDF 1 MB
TotalQuant Analysis in NexION ICP Mass Spectrometers

TotalQuant, a software feature unique to 爱游戏平台注册登录 's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information ab ...

PDF 1 MB

Training

Webinars

Baidu
map