GC 2400 System | 爱游戏平台注册登录
爱游戏平台注册登录
check quantity

GC 2400 System

Designed to address the needs for remote control, simplified and sustainable operations of analytical laboratories, the 爱游戏平台注册登录 GC 2400 System provides an innovative user experience with information on the go for effective and faster decision-making and advanced system capabilities for maximized productivity, thanks to reduced technology adoption costs and features supporting sustainability.

 

Part Number N6400000
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

The innovative 爱游戏平台注册登录 GC 2400 Gas Chromatography System allows customers to achieve unprecedented levels of efficiency. Designed to address modern analytical lab productivity, the GC 2400 System offers detachable touchscreen combined with smart sampling capabilities for faster decision making, in and outside the lab.

A new user interface collates and provides live status information on the different configured GC accessories like the 爱游戏平台注册登录 HS 2400 M Headspace Sampler using a single display. Managed by 爱游戏平台注册登录 SimplicityChrom Chromatography Data System (CDS) Software, the GC 2400 System becomes integral part of a comprehensive GC workflow.

Whether the application is industrial, environmental, pharmaceutical or in food and beverage, the GC 2400 System can help labs exceed their productivity and performance goals, delivering accurate results.

KEY FEATURES

  • Detachable touchscreen for real-time status notification
  • Programmable LEDs and sounds for immediate assessment of system status
  • Smart sampling capabilities allowing adaptation to throughput needs
  • User-replaceable detectors to allow application flexibility
  • Hydrogen sensor for safety and sustainability

爱游戏平台注册登录 AS 2400 Liquid Sampler:

  • Variety of syringes from 0.5 uL to 50 uL
  • Small (20 vial) tray and large (144 vial) tray options for maximum productivity
  • Plug-and-play driving uptime and growing with labs' needs for productivity

GC 2400 Detectors
The GC 2400 System can support up to three detectors plus mass spectrometer. Detectors can be easily interchanged, and they are self-configurable:

  • flame ionization detector (FID)
  • electron capture detector (ECD)
  • and/or single quadrupole mass spectrometer (MS 2400 SQ)

Resources, Events & More
  • All

Application Note

GC-FID: Analysis of Benzene in Compliance to United State Pharmacopeia (USP) Grade Carbomer 940

Polyacrylic acid, also known as Carbomer, is used extensively in formulations across many industries, including cosmetics, pharmaceuticals, and personal care. Carbomers are polymers of acrylic acid cross-linked with allyl ethers of pentaerythritol or sucrose forming white, lightweight polymers t ...

PDF 788 KB
GC-FID: Analysis of Residual Solvents and Monomers in Plastic

Different types of plastics are used for these diverse applications, but all plastic manufacturing has a few common raw material needs, including monomers and solvents. Plastic manufacturing workflows are designed to use all monomer input in the formation of the plastic polymer, and to remove all ...

PDF 1012 KB
GC-FID: Determination of Cetyl Alcohol and Aliphatic Alcohol Impurities According to USP

Cetyl alcohol, also known as palmityl alcohol or 1-hexadecanol, is a long-chain aliphatic alcohol that is a common additive in foods, cosmetics, personal care products (e.g., lotions and creams), and industrial fuels. To ensure cetyl alcohol quality, the United States Pharmacopoeia (USP) has outl ...

PDF 1013 KB
GC-FID: Fast and Accurate Analysis of Fatty Acid Methyl Esters (FAMEs) In Edible Oils and Food Products

The analysis of triacylglycerols by gas chromatography (GC) in their native state is challenging, largely due to their poor volatility and tnhermal decomposition in hot injector ports. To improve their properties for GC and to provide a comprehensive characterization of fatty acids, the esterifie ...

PDF 2 MB
GC/MS: Optimized Semivolatile Organic Compounds (SVOC) Analysis in Compliance with EPA Method 8270E

For more than 40 years, the United States Environmental Protection Agency (EPA) has monitored semivolatile organic compounds (SVOC) in wastes, soils/sediments, and groundwater via its Method 8270. This method is extensive in scope, targeting chemicals found in petroleum/soot (e.g., polycyclic aro ...

PDF 1 MB
HS-GC-FID: Analysis of Residual Solvents According to USP 467

Organic solvents are commonly used in the production of active pharmaceutical ingredients (API) and pharmaceutical products. The solvents are used for varying purposes including as synthesis reaction media, in the separation and purification of API during synthesis, to enhance yield, to impart de ...

PDF 1 MB
HS-GC-FID: VOC Analysis of Commercial Paint

When CASE chemicals like coatings and paints are formulated, pigments, binding agents, and additives are dissolved into a carrier solvent, often a volatile organic compound (VOC) or water. This solvent functions to lower the mixture’s viscosity, enabling it to coat a surface easily and evenly. On ...

PDF 904 KB

Article

How to Enable Sustainable GC Lab Operations?

Sustainability strategies are being integrated into a growing number of businesses and their operations. Laboratories are no exception.

Although the necessity to reduce the environmental impact of laboratory operations is recognized, it cannot be disengaged from the economic viability of l ...

PDF 577 KB
Simplifying the GC Laboratory for Improved Efficiency

Labs seek to increase the capacity of their equipment, improve turnaround times and maximize the sensitivity of their testing – without placing additional burden on their operators.

Simplification is one of the strategies of Industry 4.0 for manufacturing processes. It can also be applied ...

PDF 391 KB
What Are the Key Features of a GC Smart Connected Lab?

Interest in the potential of smart technologies was high before the pandemic hit in 2020. That interest changed to a necessity when businesses were faced with the need for remote and automated operations in order to maintain business continuity. Businesses that have embraced smart operations are ...

PDF 745 KB

Brochure

The Smart Behind Separations – GC 2400 Platform Brochure

Every day, analytical laboratories are challenged with balancing high productivity with efficient operations. And with the growing trend of hybrid work models, gas chromatography operators seek remote access to their GC – whether they’re working in a different part of the lab or at a completely d ...

PDF 782 KB

Product Note

Clearer Results with the MS 2400 SQ System Clarifi Detector

爱游戏平台注册登录 MS 2400 SQ System is designed around the cutting-edge Clarifi Detector. Engineered using the latest electron multiplier technology, the Clarifi Detector provides superior sensitivity (signal-to-noise) and the longest operational lifetime. Ions are efficiently converted into an electro ...

PDF 852 KB
Smart, Simple and Sustainable GC for More Productivity – 爱游戏平台注册登录 GC 2400 System

The innovative 爱游戏平台注册登录 2400 System allows customers to achieve unprecedented levels of efficiency. Designed to address the growing productivity and throughput needs of analytical laboratories, the GC 2400 System features a detachable touchscreen, so you can make decisions faster and be more p ...

PDF 971 KB
Uptime and Sample Throughput with Easy to Change SMARTsource Technology

The 爱游戏平台注册登录 MS 2400™ SQ Detector comes standard with SMARTsource™ (Simplified Maintenance And Removal Technology), GC/MS source easy to remove, clean and reassemble – without the need for tools. A simple twist of the SMARTsource allows users to completely remove the ion source and lenses of t ...

PDF 784 KB

Regulatory Compliance Certification

PDF 130 KB
PDF 139 KB
PDF 146 KB

White Paper

The Meteoric Rise of Solid-State Batteries: Innovations and Analytical Instrument Breakthroughs

The potential of all solid-state battery (ASSB) technology to revolutionize the battery industry is resulting in new battery designs and material configuration solutions. These advancements will unlock chemistry limitations from traditional battery technologies and enable ASSBs to break through t ...

PDF 2 MB
Baidu
map