聯用技術 | 爱游戏平台注册登录 - 爱游戏登录网,爱游戏平台注册登录
爱游戏平台注册登录

關於Revvity-- 以科技之能,突破人類潛能的邊界

(Revvity的前身是隸屬於爱游戏登录网 )


兩家獨立企業由此誕生

生命科學與診斷 & 分析和企業服務

聯用技術

通過單一儀器和個別分析技術,無法獲得結果和見解。我們的聯用解決方案可以配合兩種或更多種儀器,以大大提高分析能力,並通過從單次運行獲取更多信息節省寶貴的時間。例如:

  • 逸出氣體分析 - STA/TGA/FTIR/Imaging/GCMS
  • 形態分析 - FFF-ICP/MS, LC-ICP/MS
  • 同步分析 - STA,Imaging-Micro FTIR
  • 檢測樣品對環境的激勵 - UV-DSC, 濕度-DMA

這些技術可幫助您更好地了解物質變化規律,並將您的實驗室帶到更高的層次。知之愈多,則行之愈遠。 我們為聯用係統提供完整的服務和支持,更有相關的專家和經驗幫助您有效地使用。更重要的是,聯用係統獨家提供避免了軟件在控製多個儀器時可能出現的兼容性問題,更可以避免後續維護時出現的困難。

The More You Know, The More Your Laboratory Can Achieve

TG-IR

TG-IR: Thermogravimetric – Infrared Analysis

Because of its ability to detect functional groups in gas-phase, IR analysis allows greater understanding of the processes seen in the TGA. A sample is heated in the TGA, whereby, it decomposes and releases volatile materials and/or gaseous components as a result of material break-down. These gases Thermogravimetric properties are recorded and are then transferred to the IR cell via a high-fidelity transfer system where the components can be further characterized/identified.

A few advantages of this system include:

  • State-of-the-art - ensure transfer of every component evolved in the TGA to the IR while maintaining complete sample integrity
  • Performance - Heated zero-gravity-effect 'ZGCell' gas cell for the 爱游戏平台注册登录 FT-IR instrument incorporating automatic accessory identification, low volume, and efficient sample area purging
  • Flexibility - Switch from TG-IR mode to TGA and/or IR only mode quickly and easily

For additional information, please refer to the Evolved Gas Analysis Guide below.

TG-MS

TG-MS: Thermogravimetric - Mass Spectrometry Hyphenated Analysis

The ability to detect very low levels of impurities in real time makes TG-MS a powerful tool for quality control, safety, and product development. Samples heated in the TGA release volatile materials and/or generate gaseous components that are seamlessly transferred via a high-fidelity transfer system to the MS for identification.

A few advantages of this system include:

  • State-of-the-art -The TG-MS is equipped with a transfer line with adjustable heating capabilities up to 350 °C, a mass flow control, and pumps
  • Performance - TG-MS enables high sensitivity measurements in real time
  • Flexibility - Switch from TG-MS mode to TGA and/or MS only mode quickly and easily

For additional information, please refer to the Evolved Gas Analysis Guide below.

TG-GC/MS

TG-GC/MS: Thermogravimetric - Gas Chromatography/Mass Spectrometry

The ability to detect very low levels of material (known and unknown) in complex mixtures makes the TG-GC/MS a powerful tool for quality control, safety, and product development. Heating a sample on the TGA causes a sample to release volatile materials and/or generate gaseous components upon decomposition. These gases are then transferred via a high-fidelity heated transfer system to the GC, where the components can be collected on a trapping media, in a gas sampling loop, or deposited on the head of a column. The sample can then be run by GC to separate the material, and the peaks identified by the MS.

A few advantages of this system include:

  • FAST GC capable with the Clarus 690, benefits of FAST GC include:
    • Faster results with time savings up to 80%
    • Analyze multiple events in a single run
    • Double event separation
    • Automatic triggering by time or weight loss
  • Better than Pyrolysis
    • See the decomposition and choose when to start sampling
    • Choose to analyze individual losses to identify what they are
    • Analyze the total weight loss to quantify the percentage of that component in the sample
  • Better Separations & Detection of lower-level impurities than TG-MS
  • Flexibility –switch from GC separation (TG-GC/MS mode) to Single Ion Monitoring (TG-MS mode) to TGA and/or GC/MS only mode quickly and easily

For additional information, please refer to the Evolved Gas Analysis Guide below.

TG-IR-GC/MS

TG-IR-GC/MS: Thermogravimetric - Infrared - Gas Chromatography/Mass Spectrometry

Hyphenating TG-IR-GC/MS is a powerful approach for analysis of an unknown mixture to determine its primary components and identify additives or contaminants. This information may be needed to evaluate a competitor’s product, determine compliance with regulations, or understand a material’s composition. The 爱游戏平台注册登录 TG-IR-GC/MS high-fidelity heated transfer system enables TG-IR-GC/MS analysis on a sample by moving every component in the off gases to the FT-IR and/or GC/MS after their evolution in the TGA while maintaining complete sample integrity.

A few advantages of this system include:

  • Performance - Maintains the relationship between the temperature each gas is released at and its corresponding components through FT-IR
  • Sensitivity - The sequentially measuring of the off-gas components by GC/MS enables detection of trace levels too low to be seen in the FT-IR
  • FAST GC capable with the Clarus 690, benefits of FAST GC include:
    • Faster results with time savings up to 80%
    • Analyze multiple events in a single run
    • Double event separation
    • Automatic triggering by time or weight loss
  • Flexibility - Switch from TG-IR-GC/MS mode to TGA, IR, GC/MS and/or GC mode quickly and easily For additional information, please refer to the Evolved Gas Analysis Guide below.

For additional information, please refer to the Evolved Gas Analysis Guide below.

Digital Controller and Pump

All 爱游戏平台注册登录 EGA Hyphenation systems include the master digital controller and pump, that ensures balanced flow while controlling temperature, flow, and pressure. The controller includes temperature controlling devices, mass flow controller (MFC), flow smoothing system, filters and pump with exhaust line.

A few benefits include:

  • 7” Touchscreen display
  • Easy MFC calibration from control panel
  • Alert notifications displayed on control panel for immediate diagnostics
  • Set pump threshold activation/time prior to shutdown
  • Web server enabled – allows Remote Control from Any PC

For additional advantages & benefits, refer to the Evolved Gas Analysis Guide below.

Applications of Hyphenated Technologies

    TG-IR TG-MS TG-GC/MS TG-IR-GC/MS
Industrial Bio-polymers gases degradation    
Chemical Identification      
Competitive analysis      
Fire Retardation (performance evaluation and identification)      
Graphene and CNT based batteries proof of successful hybridization      
Nanomaterials  
Packaging materials
Petroleum, Lubricants, and Coal QA/QC & Research      
Polymer additives  
Process optimization  
Pyrolysis    
QA/QC
Thermal Stability    
 
Food Additives      
Adulteration
Carbohydrate analysis      
Fats and Oils      
Food Packaging  
Food quality  
Moisture analysis  
Pyrolysis    
State transitions      
 
Environmental Contaminated soil  
Formulation analysis      
Microplastics      
Moisture analysis      
Residual solvent      
Trace amount Detection  
 
Pharmaceutical Crystal shape evaluation  
Excipients compatibility    
Formulation analysis    
Moisture analysis      
Residual solvent
Shelf life    
Solid state characterization (polymorphism/pseudopolymorphism)      
Solvates  
Solvent-molecule binding energy      
Thermal degradation    
 
Academia & R&D Alkanes, cycloalkanes, aromatic hydrocarbons, and asphaltenes      
Battery research (i.e. lithium polymer (LiPo) electrolyte (SPE)      
Crystal Shape Evaluation      
Decomposition studies  
Kinetic Analysis (i.e. pyrolysis, catalysis etc.      
Material Characterization      
Material Sciences  
Nanomaterials    
Polymers      
Polymer separation and degradation      
Pyrolysis    
Solvent molecule binding energy    
State transitions      
Unknown identification  