爱游戏平台注册登录

Introducing Revvity - Expanding the boundaries of human potential through science

(Revvity was previously affiliated with 爱游戏平台注册登录 , Inc.)

We are now two standalone organizations

Life Sciences & Diagnostics and Analytical & Enterprise Solutions

Mass Spectrometry - Translational Research System

Better LC/MS/MS detection, whatever your application

METABOLOMICS

This quickly evolving field specializes in measuring unique chemical fingerprints generated during cellular function and is a crucial component of systems biology research. The varied chemical nature of these biomarkers makes the robust QSight 220 Clinical Research System a perfect instrument for measuring metabolic signatures from complex biological sample types.

PROTEOGENOMICS

Proteogenomics is a newly emerging field that harnesses the combined insight of genetic information and transcriptional proteomic analysis. The QSight system's workflow uses that genetic information to predict and validate variant insights by mass spectral analysis of unique peptides associated with target proteins and biomarkers of interest.

PERSONALIZED MEDICINE

The convergence of pharmacokinetics and metabolomics has driven the need for dynamic results as the field of precision medicine aims to provide optimal personalized care based on accurate and sensitive biological measurements. The QSight system’s triple quad technology harnesses the power of mass spec to provide industry-leading accuracy, reliability, and reproducibility for biomarker discovery and analysis, regardless of sample type.

The QSight® 220 Clinical Research System adds the power of triple quadrupole mass spectrometry to 爱游戏平台注册登录 ’s suite of clinical research solutions. Backed by years of research, the QSight 220 Clinical Research System includes several innovative solutions designed to increase robustness and reduce the need for maintenance, allowing you to spend your time doing your research, not cleaning your system.

The 爱游戏平台注册登录 QSight® LX50 UHPLC system is the perfect complement to the QSight LC/MS/MS platform: Featuring a high precision autosampler, an advanced UHPLC solvent delivery module and a flexible column temperature module, the QSight 220 Clinical Research System delivers the performance required for even the most demanding analyses. With the addition of mass spectrometry, 爱游戏平台注册登录 is uniquely positioned to understand and meet your clinical research needs. From automated sample preparation to data acquisition and analysis, to outstanding post-sale and technical support, 爱游戏平台注册登录 has your lab covered.

For research use only. Not for use in diagnostic procedures.

QSight® Triple Quadrupole LC/MS/MS Platform

High sensitivity, even higher productivity

Unique StayClean technology employs hot-surface induced desolvation (HSID), a multi-orthogonal sampling interface that can significantly increase your uptime. A continuous flow of hot gas forms a barrier that prevents most of the ions or clusters from hitting the side walls. It also acts as a constant cleaning agent that flushes away any potential deposits. Plus, solvated charged species are entrained and desolvated in the hot flow of gas, reducing chemical noise and delivering a higher signal-to-noise ratio.

Go with the flow

Ions are transferred from the HSID interface to the system’s Laminar Flow Ion Guide, then moved to the analyzing region by a flow of background gas – no axial electrical fields are necessary. This means the system is not susceptible to field fluctuations and delivers consistently high levels of performance. Instrument drift and frequent re-optimization and cleaning are eliminated, for better productivity.

Two sources are better than one

The system's dual-source technology has two separate ion inlets that operate independently and can be set in ESI or APCI modes, enabling combinations such as ESI/ESI, ESI/APCI, and APCI/APCI – with the same or opposite polarities. Unlike single-source instruments, our dual-source technology enables you to collect data in two complementary modes, maximizing the output from a single injection. Plus, it enables you to employ one probe for tuning and another probe for high flow analysis, giving you the capabilities of two MS systems in one.

See how easy it is to switch

With its high-energy dynode to attract positive ions, the QSight system’s UniField Detector causes positive ions to collide with the dynode to form electrons (which cascade into the detector) while negative ions are detected as usual for pulse counting. What you get is near-simultaneous detection of positive and negative ions without the need for high-voltage switching. Polarity switching happens in microseconds, limited only by the ion source and ion path polarity switching – not by the detector.

Learn More

Application Notes

Measurement of Immunosuppressants in Whole Blood

The QSight® 200 series UHPLC-MS/MS system equipped with SP50® online solid phase extraction offers an excellent tool for the determination and quantification of ...

Learn More

Measurement of Homovanillic Acid, Vanillylmandelic Acid & 5-HydroxyIndoleAcetic Acid in Urine

Discover a fast and reliable UHPLC-MS/MS method for the determination of HVA, VMA, and 5-HIAA acid in urine using the QSight 200 series mass spectrometer and a ...

Learn More

Measurement of Cortisol & Cortisone in Urine

Simultaneous detect and quantify cortisol and cortisone in urine using the QSight 200 series mass spectrometer coupled with a commercially available kit.

Learn More

Measurement of Remdesivir & Its Metabolite GS-441524 in Plasma

Sensitive and accurate determination of remdesivir and GS-441524 in human plasma samples for pharmacokinetic and pharmacodynamic studies of remdevisir.

Learn More

Measurement of Catecholamines & Metanephrines in Urine

Get sensitive and accurate determination of catecholamines and metanephrines in urine samples with the QSight® 200 series UHPLC-MS/MS system.

Learn More

Rapid Quantitative Analysis of Vitamin D Metabolism with Nanogram Detection

The metabolites of vitamin D have a critical physiological function to maintain calcium and phosphate homeostasis. In order to determine levels vitamin D, both ...

Learn More

A Quantitative Determination of Methadone and its Metabolite (EDDP) in Dry Blood Spots Using LC-MSMS

The present research study provides a much simplified approach whereby a highly sensitive LC-MS/MS triple quadrupole mass spectrometer is used to measure direct ...

Learn More

Steroid Panel Analysis with the 爱游戏平台注册登录 QSight® 220 Triple Quadrupole Mass Spectrometer

Achieving adequate sensitivity across the whole panel is quite difficult because optimum ionization conditions vary depending on the steroid.

Learn More

High Throughput, Reliable Quantitation of 25-hydroxyvitamin D in Serum

Vitamin D is a group of fat-soluble hormones, which have the two major forms: D2 (ergocalciferol) and D3 (cholecalciferol). The metabolites of vitamin D have a ...

Learn More

Metanephrine and Normetanephrine Quantification by SPE-LC-MS/MS

Measurement of metanephrines and normetanephrine in plasma is challenging due to the low physiological concentrations, their hydrophilic nature1, and time consu ...

Learn More

High Throughput LC-MS/MS Assay of Phthalates Using 爱游戏平台注册登录 QSight® 220 LC-MS/MS

Phthalates are a family of chemicalscommonly used as plasticizers toincrease the flexibility, transparency,durability, and longevity of plastics.These compounds ...

Learn More

Testosterone Detection at Low Femtogram Levels

The QSight® 220 triple quadrupole mass spectrometer provides excellent sensitivity, linearity and stability and is easily able to quantify testosterone at level ...

Learn More

High Sensitivity Methotrexate Quantitation in Human Serum Utilizing

This application note outlines a rapid LC-MS/MS research method utilizing the QSight® 220 triple quadrupole mass spectrometer. The developed method provides exc ...

Learn More

Rapid, High Throughput Analysis of Compounds in Urine

Urine is the matrix of choice as it can be collected easily and in large volumes. The variations within the urine matrix can adversely impact chromatographic se ...

Learn More

Low Attomole Quantitation of Bio-Therapeutic Peptides in Human Plasma

With an increasing number of peptide-based drugs being developed and used in the market, reliable, rapid and sensitive quantitation methods are needed. Although ...

Learn More

A New, Sensitive Method for Lignan Metabolite Detection of Flaxseed-Fed Mice

Dietary phytochemicals such as polyphenols, carotenoids, saponins and glucosinolates have been suggested to play important roles in human health and may contrib ...

Learn More

Applications and Solutions

Liquid Handling Instruments

Enable you to minimize errors, reduce hands-on time, and increase throughput and reproducibility.

Learn More

Flexible JANUS® G3 Automated Workstations

Portfolio of precision liquid handling solutions that provide adaptability in throughput.

Learn More

ChemDraw

The gold standard for Chemical Drawing and Research publications

Learn More

Need More Information About the QSight Triple Quadrupole LC/MS/MS?

Baidu
map