For research use only; not for diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption & disposal requirements under European REACH regulations (EC 1907/2006).
AlphaLISA Acceptor beads conjugated to anti-HA (hemagglutinin) antibody. These beads can be used to capture HA-tagged proteins and peptides, and can be used in conjunction with Alpha Donor beads to create AlphaLISA no-wash assays for:
In a typical AlphaLISA assay, 1 mg of AlphaLISA Acceptor beads is sufficient to run 1,000-2,000 wells using a 50 µL final reaction volume. Bead concentration can be adjusted for optimal performance.
AlphaScreen® and AlphaLISA® are bead-based assay technologies used to study biomolecular interactions in a microplate format. The acronym "Alpha" stands for amplified luminescent proximity homogeneous assay. As the name implies, some of the key features of these technologies are that they are non-radioactive, homogeneous proximity assays. Binding of molecules captured on the beads leads to an energy transfer from one bead to the other, ultimately producing a luminescent/fluorescent signal. To understand how a signal is produced, one must begin with an understanding of the beads. AlphaScreen and AlphaLISA assays require two bead types: Donor beads and Acceptor beads. Each bead type contains a different proprietary mixture of chemicals, which are key elements of the AlphaScreen technology. Donor beads contain a photosensitizer, phthalocyanine, which converts ambient oxygen to an excited and reactive form of O2, singlet oxygen, upon illumination at 680 nm. Please note that singlet oxygen is not a radical; it is molecular oxygen with a single excited electron. Like other excited molecules, singlet oxygen has a limited lifetime prior to falling back to ground state. Within its 4 µsec half-life, singlet oxygen can diffuse approximately 200 nm in solution. If an Acceptor bead is within that proximity, energy is transferred from the singlet oxygen to thioxene derivatives within the Acceptor bead, subsequently culminating in light production at 520-620 nm (AlphaScreen) or at 615 nm (AlphaLISA). In the absence of an Acceptor bead, singlet oxygen falls to ground state and no signal is produced. This proximity-dependent chemical energy transfer is the basis for AlphaScreen's homogeneous nature.
抗體偶聯物 | Anti-HA |
---|---|
自動化兼容 | Yes |
檢測方法 | Alpha |
實驗類型 | In vitro |
Format | Microplates |
產品品牌名稱 | AlphaLISA |
運輸條件 | 藍冰 |
產品尺寸 | 25 mg |
The interactions and bindingof proteins are implicated in a large number of biological processes. The needfor an efficient, highly sensitive assay to study large protein interactions is increasingly important. Alpha Technology is a highly flexible, homogeneous, no-wash assay ideal for the measuremen ...
Anti-inflammatory monoclonal antibody drugs that specifically target TNFα, such as Humira®, have been highly successful in the market. As patents expire on these top-selling drugs, effort has been placed on developing biosimilars. Biosimilars differ from small molecule generi ...
The introduction of enzyme-linked immunosorbent assays (ELISAs) in the early 1970’s offered researchers a non-radiometric immunoassay platform without compromising sensitivity. Over the last 50 years scientists have made huge strides in disease research and drug discovery and a demand for greater ...
Binding events between biomolecules are important components of biological processes and a number of these biomolecular interactions have been targeted for the development of novel therapeutic drugs. p53 is a transcription factor and tumor suppressor protein that is activated in response to cellu ...
Alpha has been used to study a wide variety of interactions, including protein:protein, protein:peptide, protein:DNA, protein:RNA, protein:carbohydrate, protein:small molecule, receptor:ligand, and nuclear receptor:ligand interactions. Both cell-based and biochemical interactions have been monitored ...
AlphaScreen® and AlphaLISA® are bead-based assay technologies used to study biomolecular interactions in a microplate format. The acronym “Alpha” stands for Amplified Luminescent Proximity Homogeneous Assay. The assay does not require any washing steps. Binding of proteins or other binding partners ...
This guide presents the simple conversion of an ELISA or other immunoassay to an AlphaLISA® immunoassay.