check quantity

Fc-fragment (human) conjugated AlphaLISA Acceptor Beads, 5 mg

AlphaLISA® Acceptor beads conjugated to human IgG Fc fragment. These beads can be used to capture Fc binding proteins and receptors.

For research use only; not for diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption & disposal requirements under European REACH regulations (EC 1907/2006).

Part Number
Unit Size
List Price
Your Price
Quantity
AL174C
250 µg
1158.00 USD
 
more
AL174M
5 mg
8900.00 USD
 
more
AL174R
25 mg
35300.00 USD
 
more
爱游戏平台注册登录 Life Sciences & Diagnostics is now Revvity, but at this time, there is no change to the supplier information.
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

These beads can be used in conjunction with Alpha Donor beads to create AlphaLISA no-wash Fc receptor binding assays.

In a typical AlphaLISA assay, 1 mg of Acceptor beads is sufficient to run 1,000-2,000 wells using a 50 µL reaction volume.

Features:

  • No-wash steps, no separation steps
  • Ease-of-use: few addition steps, fast assay development
  • Broad range of affinities: detect strong or weak interactions, from pM to mM affinity
  • Distance: measure very large protein or antibody complexes – spanning up to 200 nm or more
  • High avidity: multiple binding sites on each bead enables use of nanomolar concentrations of antibodies or proteins, as well as use of low affinity binders

AlphaScreen® and AlphaLISA® are bead-based assay technologies used to study biomolecular interactions in a microplate format. The acronym "Alpha" stands for amplified luminescent proximity homogeneous assay. As the name implies, some of the key features of these technologies are that they are non-radioactive, homogeneous proximity assays. Binding of molecules captured on the beads leads to an energy transfer from one bead to the other, ultimately producing a luminescent/fluorescent signal. To understand how a signal is produced, one must begin with an understanding of the beads. AlphaScreen and AlphaLISA assays require two bead types: Donor beads and Acceptor beads. Each bead type contains a different proprietary mixture of chemicals, which are key elements of the AlphaScreen technology. Donor beads contain a photosensitizer, phthalocyanine, which converts ambient oxygen to an excited and reactive form of O2, singlet oxygen, upon illumination at 680 nm. Please note that singlet oxygen is not a radical; it is molecular oxygen with a single excited electron. Like other excited molecules, singlet oxygen has a limited lifetime prior to falling back to ground state. Within its 4 µsec half-life, singlet oxygen can diffuse approximately 200 nm in solution. If an Acceptor bead is within that proximity, energy is transferred from the singlet oxygen to thioxene derivatives within the Acceptor bead, subsequently culminating in light production at 520-620 nm (AlphaScreen) or at 615 nm (AlphaLISA). In the absence of an Acceptor bead, singlet oxygen falls to ground state and no signal is produced. This proximity-dependent chemical energy transfer is the basis for AlphaScreen's homogeneous nature.

Specifications

Antibody Conjugates Human Fc-fragment
Automation Compatible Yes
Bead Type or Core Bead Type AlphaLISA Acceptor
Detection Method Alpha
Product Brand Name AlphaLISA
Shipping Condition Blue Ice
Unit Size 5 mg
Resources, Events & More
  • All

Application Brief

Eight Limitations of ELISA and How to Overcome Them Using Alternative Technologies

The introduction of enzyme-linked immunosorbent assays (ELISAs) in the early 1970’s offered researchers a non-radiometric immunoassay platform without compromising sensitivity. Over the last 50 years scientists have made huge strides in disease research and drug discovery and a demand for greater ...