Oxygenate and Aromatic Analyzers - Model 4013 | 爱游戏平台注册登录
爱游戏平台注册登录
check quantity

Oxygenate and Aromatic Analyzers - Model 4013

Understanding the composition of finished gasoline is paramount to ensure that a safe and quality petroleum product is delivered to downstream oil and gas customers. 爱游戏平台注册登录 ’s portfolio of oxygenate and aromatic analyzers are engineered specifically to meet the needs of customers producing finished gasoline products. Our analyzers can be used to determine ether and alcohol additives in finished gasoline products, as well as benzene, toluene, ethylbenzene and other aromatics as required. Trace methanol, acetaldehyde, MTBE, acetone, 2-propanol can also be analyzed in some models. Once installed, samples can be processed immediately, allowing you to optimize instrument up-time and productivity from day one.

Part Number
Type
Detection Method
Detector Type
NARL6503
Model 4080
EN 12177, EN 13132 and IP 425/96
FID
more
NARL8500
Model 4001
ASTM D4815
TCD
more
NARL8501
Model 4002
ASTM D4815
FID
more
NARL8410
Model 4015
ASTM D3608, ASTM D4815, ASTM D5580
FID
more
NARL8511
Model 4012
ASTM D4815, ASTM D5580
TCD/FID
more
NARL8503
Model 4004
ASTM D4815, ASTM D5580
FID
more
NARL8512
Model 4013
D3606
TCD
more
NARL8513
Model 4014
ASTM D3606
TCD
more
NARL8528
Model 4080
EN 12177, EN 13132 and IP 425/96
TCD
more
NARL8551
Model 4086
ASTM D7423 D7754 and UOP 960
FID
more
NARL8504
Model 4005
ASTM D5580
FID
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

For users needing to test finished gasoline samples for benzene and toluene by ASTM D3606 with no modifications for oxygenate fuels, Model 4013 utilizes a single channel with the option for an additional channel to create a custom analyzer solution. Aromatic and non-aromatic compounds are measured utilizing a thermal conductivity detector (TCD), with reference to the internal standard methyl-ethyl ketone (MEK). As ethanol co-elutes with benzene, this Model is not suitable for samples containing ethanol. For such samples, Models 4012 and 4014 are suitable options. Detection limits for benzene are 0.1% - 5%, and 2 – 20% for toluene.

Specifications

Detection Method D3606
Detector Type TCD
Product Compatibility Clarus 590 PPC
Type Model 4013
Resources, Events & More
  • All

Application Note

Analysis of Oxygenates and Aromatics Using ASTM Method D4815 and D5580

Gasoline samples are complex and a single column solution is not always readily available for the required analysis. As such, solutions that have multiple columns, valves, backflushing and heartcutting ability have been developed to overcome these challenging separations. The resulting standardi ...