We are now two standalone organizations
Life Sciences & Diagnostics and Analytical & Enterprise Solutions

×
×

We are now two standalone organizations

  • Life Sciences & Diagnostics

    A Life Sciences and Diagnostics business focused on enabling scientists and healthcare professionals to advance research, discovery and detection to improve global health

  • Analytical & Enterprise Solutions

    An Analytical and Enterprise solutions business, including leading OneSource laboratory services, focused on accelerating scientific outcomes

Avio 220 Max ICP-OES Scott/Cross-Flow Configuration | 爱游戏平台注册登录
爱游戏平台注册登录
check quantity

Avio 220 Max ICP-OES Scott/Cross-Flow Configuration

The Avio® 220 Max is a compact, hybrid simultaneous ICP-OES instrument, ideal for labs with low-to-medium throughput requirements. Its unique plug-and-play capabilities make the Avio 220 Max the ICP with the fastest startup on the market – cold start to analysis in only 10 minutes – saving you time and operating costs by allowing you to shut down the instrument between runs. Plus, it utilizes a vertical plasma and is engineered to handle even the most difficult, high-matrix samples without dilution, delivering productivity, performance and faster return on investment. And last but certainly not least, Syngistix for ICP software provides an intuitive and smart environment with smart monitoring for real-time instrument and sample diagnostics as well as results viewing to easily track sample analysis, quality control, and internal standard performance to guarantee sample accuracy.

Part Number
Model Name
N0790004
Avio 220 Max Scott/Cross-Flow
more
N0790005
Avio 220 Max Concentric/Cyclonic
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Proprietary features on the Avio 220 Max ICP-OES include:

  • Plug-and-play functionality allows for fast startup – cold start to analysis in just 10 minutes
  • Simultaneous acquisition of analyte and background with increased analyte sensitivity
  • Flat Plate plasma technology delivers a more robust, stable plasma, the lowest argon consumption of any ICP, and is maintenance-free
  • PlasmaShear system offers maintenance-free, argon-free interference removal
  • Attenuation mode reduces the signal without manual dilution, with just a click of a button, and is fully customizable by each wavelength
  • Vertical plasma torch design provides 100% matrix tolerance, minimizing sample preparation time
  • Dual view optimizes axial and radial plasma viewing to the extended linear dynamic range, measuring high and low concentrations in the same run, regardless of wavelength
  • Double-monochromator optical system brings outstanding analytical performance
  • Color PlasmaCam provides continuous viewing of the plasma, simplifying method development and enabling remote diagnostic capabilities
  • Syngistix for ICP Software delivers an intuitive, left-to-right, icon-based design, mirroring the progression of your workflow with smart features that guide you through each step for greater control and confidence

And for added flexibility, the Avio 220 Max is available in two configurations, allowing you to select the option best suited for your application(s). This configuration of the Avio 220 Max is equipped with Scott/Cross-Flow sample introduction, suitable for most applications even those requiring hydrofluoric acid.

Specifications

21 CFR Part 11 Compatible Yes
Depth 76.0 cm
Height 81.0 cm
Model Name Avio 220 Max Scott/Cross-Flow
Warranty 1 Year
Weight 100.0 kg
Width 65.0 cm
Resources, Events & More
  • All

Application Note

Analysis of Aluminum Alloys with the Avio 220 Max ICP-OES Following London Metal Exchange Guidelines

Due to its unique characteristics, aluminum (Al) is used in a wide variety of commercial and industrial applications. Its utility can be further enhanced by combining it with other metals to create aluminum-based alloys, where the non-aluminum additives can make up to 15% of the total alloy, by w ...

PDF 1 MB
Analysis of Copper-Gold Ore with the Avio 220 Max ICP-OES

The extraction of metals from ore at a mining plant requires the routine analysis of various samples, which include the feed (crushed ore), the tails (waste ore after processing) and the concentrate (final product). In this work, reference materials were analyzed for copper (Cu), iron (Fe), silve ...

PDF 1 MB
Analysis of Impurities in Aluminum with the Avio 220 Max ICP-OES Following London Metal Exchange Guidelines

Due to aluminum’s varied uses and popularity, there are many grades available. The London Metal Exchange (LME) lists specifications for two commonly-used aluminum (Al) purities: 99.5% and 99.7%1, with each having up to six inorganic impurities specified. ICP-OES is the best technique for measurin ...

PDF 1 MB
Analysis of In-Service Oils Following ASTM D5185 with the Avio 220 Max ICP-OES

With heavy machinery, it is important to assess its status during operation to prevent breakdowns and costly repairs. A key aspect is monitoring the status of the oil or lubricants used to lubricate various components such as engines, transmissions, gearboxes and many other important areas: if th ...

PDF 1 MB
Analysis of Macronutrients in Pet Food with the Avio 220 Max ICP-OES

Our pets’ diet should provide essential nutrients in the correct quantities to ensure their proper nutrition. These nutrients include vitamins, essential fatty acids, proteins, amino acids, and minerals, all of which support a pet’s wellbeing, keeping them happy and healthy. Inductively coupled p ...

PDF 732 KB
Analysis of Micronutrients in Fruit Juice Using the Avio 220 Max ICP-OES

For food manufacturers and processors, it is important to be able to quantify the content of food products, including micronutrients, for both safety and quality reasons along with regulatory label-claim requirements, and ICP-OES is generally favored in a multi-element analytical environment with ...

PDF 1 MB
Analysis of Micronutrients in Milk Using the Avio 220 Max ICP-OES

With its great importance, milk is available in several different forms: fresh, boxed (ultraheat treated), powdered, and evaporated. The most commonly consumed form varies globally, being dependent on factors such as geography, culture, and climate. For milk producers, internal quality control an ...

PDF 1 MB
Analysis of Midstream Refining Products from Palm Oil Processing with the Avio 220 Max Hybrid Simultaneous ICP-OES

Palm oil and its byproducts are used in a wide variety of industries and products, including foods, pharmaceuticals, personal care, energy, agriculture, as well as in the production of oleochemicals. Extracting and refining oil from palm trees and fruits is a complex, multi-step process which can ...

PDF 382 KB
Analysis of Oil Additives Following ASTM D4951 with the Avio 220 Max ICP-OES

When blending base oils and additives for use as lubricants, it is important to know and control the concentrations of certain elements for optimal performance and longer engine life. Because this process is so crucial, ASTM developed a method for monitoring this procedure – ASTM method D4951 – w ...

PDF 1 MB
Analysis of Plating Bath Solutions with the Avio 220 Max ICP-OES using Attenuation Mode

Routine analysis of plating bath solutions is critical in order to maintain the recommended formulation, but presents several challenges: the presence of particulates, the need to monitor different element groups during a typical analysis day, and the need to accurately measure high concentration ...

PDF 899 KB
Analysis of SiO2- and TiO2-Containing Medications by ICP-OES per USP 232/233 with Software to Aid in 21 CFR Part 11 Compliance

Since early 2018, manufacturers of pharmaceutical products are mandated to comply with USP <232/<233> requirements around the analysis of elemental impurities in medications. This work demonstrates the ability of 爱游戏平台注册登录 ’s Avio® 220 Max hybrid simultaneous ICP-OES to pass valid ...

PDF 2 MB
Analysis of Trace Elements in Fertilizer with the Avio 220 Max ICP-OES

The production of fertilizer is a key industry for a country's agricultural sector, with the main benefit of increasing crop productivity. The primary elements of interest in fertilizers are categorized into four classes: primary nutrients, secondary nutrients, micronutrients, and trace elements. ...

PDF 1 MB
Arsenic and Selenium in Drinking Water by ICP-OES with Continuous Flow Hydride Generation and a Single Pre-Reduction Procedure

The determination of arsenic (As) and selenium (Se) by ICP-OES is challenging because both elements are weak emitters, which makes it difficult to measure low concentrations. In addition, in many sample types, both As and Se are present in low concentrations; the combination of low concentrations ...

PDF 1 MB
Direct Analysis of Impurities in Lithium Hexafluorophosphate Battery Electrolyte with the Avio 220 Max ICP-OES

As a power supply for green energy, lithium-ion batteries (LiBs) are being widely used across many fields, therefore their increased performance and safety are becoming the new challenge for LiBs manufacturers and researchers.

 

Among all the components in LiBs, the electrolyte is the most ...

PDF 1 MB
Early Detection of Chloride in 3-MCPD Precursors in Palm Oil through Edible Oils Analysis with Avio 220 Max ICP-OES

During the production of palm oil, 3-MCPD forms from the reaction of acylglycerol with the chloride ion (Cl-). 3-MCPD is a potentially carcinogenic compound, with a tolerable daily intake of 2 µg/kg of bodyweight. As a result, the palm oil industry limits the 3-MCPD concentration to le ...

PDF 1 MB
Measurement of Cesium, Lithium, and Rubidium in Desalination Discharge Brines with the Avio 220 Max ICP-OES

The main source of elements and minerals has traditionally been mining from geological deposits in the earth. While an effective strategy for many elements, it is not the most efficient for elements which are not naturally abundant at high concentrations. In addition, for elements which are in hi ...

PDF 1 MB
Meeting the Challenges of Soil Analysis with the Avio 220 Max ICP-OES

The analysis of soils for elemental contents presents challenges during the sample preparation step. A common method for preparing a soil sample for inorganic elemental analysis involves digesting the soil sample in an acid that is heated to near-boiling to extract the elements for analysis. When us ...

PDF 1 MB
Meeting the RoHS Directive with Microwave Sample Preparation and the Avio 220 Max ICP-OES

With the increasing demand for electronics, manufacturers are continually developing new products with enhanced capabilities, and consequently, the lifetime of electronics is becoming shorter as consumers more frequently upgrade to newer, more advanced models. The result is an increasing number o ...

PDF 537 KB
The Analysis of Brines with the Avio 220 Max ICP-OES

The most common form of brines is sodium chloride (NaCl)-based. These are used primarily in the production of chlorine gas (Cl2) via electrolysis and the polymeric membrane cell process, in which brines are passed through an ion-exchange membrane, where the brine is de-chlorinated via ...

PDF 1 MB
Total Chlorine in Palm Trees for Early Detection of 3-MCPD in Refined Oil with Avio 220 Max ICP-OES

The popularity of palm oil and its many end products has been growing rapidly. However, due to the possible presence of 3-monochloropropane-1,2-diol (3-MCPD) generated during the refinery process, refined palm oil can have potential health risks to the consumer. 3-MCPD is the product of the chemi ...

PDF 358 KB

Brochure

A Complete Portfolio of Grain Testing Solutions

Grains, whether consumed whole or processed, have nutritional and functional requirements and must be safe for consumption, and the only way to ensure grain quality is through rigorous testing. That’s where 爱游戏平台注册登录 come in. Our easy-to-operate, integrated testing and analytical solutions enco ...

PDF 1 MB
Automotive Materials Analysis Brochure

This brochure guides you through all our 爱游戏平台注册登录 analytical solutions for the automotive industry. From advanced polymers and rubber materials, to batteries, semiconductors, glass, fuels and lubricants. See how we can offer you fully-rounded laboratory solutions along the whole automotive val ...

PDF 2 MB
Avio Max Series ICP-OES Interactive Brochure

Nowadays, laboratories are expected to tackle quick turnaround times and meet lower detection limits, while at the same time deliver high levels of sample accuracy – and although workloads and workflows may vary, the need to work quickly doesn’t. Plus, labs are looking to lower operating costs an ...

PDF 3 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, ...

PDF 3 MB
In-Depth Battery Component Testing

As the world moves to embrace renewable energy sources and reduce our global CO2 emissions, it will also be more dependent than ever on better battery technology, powering the demands of industries such as automotive, energy storage, and portable consumer goods like power tools, computers, and ph ...

PDF 2 MB

Flyer

Syngistix for ICP Software – Only 3 Clicks to Results

For labs conducting routine elemental analysis, simplified and streamlined workflows are critical to success. Syngistix for ICP software for the Avio® Max ICP-OES series is engineered with an assortment of smart features, streamlining analysis with only three clic ...

PDF 469 KB

Guide

Atomic Spectroscopy - A Guide to Selecting the Appropriate Technique and System

Atomic spectroscopy is a family of techniques for determining the elemental composition of an analyte by its electromagnetic or mass spectrum. Several analytical techniques are available:

  • Atomic absorption (AA): flame and graphite furnace
  • Inductively coupled plasma optical emis ...

PDF 1 MB
Battery Analysis Guide

This guide offers an overview of analyses required throughout the battery value chain - learn about innovative analytical solutions for testing every part of the battery, including the anode, cathode, binder, separator, and electrolyte. See the value in data generated from a variety of applicatio ...

PDF 2 MB

Poster

Advanced Solutions for Solar Cells Poster

Download this poster for an all-in-one view of how 爱游戏平台注册登录 instrumentation can answer the analytical needs of the solar market. From R&D of nanomaterials and advanced materials to solar cell component testing including aging and defect analysis - our UV/Vis, DSC, TGA, FT-IR and ICP systems he ...

PDF 1 MB

Product Note

Avio 220 Max Hybrid Simultaneous ICP Optical Emission Spectrometer

The Avio® 220 Max, the industry's only hybrid simultaneous ICP-OES, is a robust and matrix-tolerant system with plug-and-play performance taking you from cold start to analysis in just 10 minutes – ideal for labs with low-to-mid throughput requirements. The instrument’s performance ...

PDF 627 KB
Syngistix Cross-Platform Atomic Spectroscopy Software

爱游戏平台注册登录 's Syngistix is a workflow-based software designed to offer a harmonized user experience across 爱游戏平台注册登录 ’s AA, ICP and ICP-MS platforms.

PDF 757 KB
Syngistix for ICP - Smart Software for Every Workflow

Syngistix for ICP software boasts a number of smart features designed to optimize your workflows and the performance of the Avio® Max ICP-OES instruments – from initial instrument setup to final results – for consistent, efficient, reliable operation. Flexible and ...

PDF 1 MB

Regulatory Compliance Certification

Product Certificate - Avio 200 and Avio 200 Max Series

Product Certificate for the Avio 200 and Avio 200 Max Series

PDF 98 KB

Technical Note

Advantages of 爱游戏平台注册登录 's PlasmaShear Technology for ICP-OES

ICP-OES is a rugged, robust technique capable of analyzing complex matrices containing percent levels of dissolved solids without the need for dilution. Nevertheless, to ensure accurate, robust analyses several challenges must be overcome. Two important obstacles are self-absorption by the plasma ...

PDF 608 KB
Attenuation Mode on the Avio 220 Max ICP-OES for Simplified Analysis of High Concentration Elements

In ICP-OES analyses, it is common to measure elements present at high concentrations, such as minerals, matrix elements in alloys, and plating bath solutions, to name just a few examples. However, when concentrations are too high, the response becomes non-linear, which can lead to inaccurate resu ...

PDF 1 MB
Avio 220 Max ICP-OES Custom-Designed Solid-State Detector with Hybrid Simultaneous Analysis

The Avio® 220 Max hybrid simultaneous ICP-OES features a dual backside illuminated charge-coupled device (DBI-CCD) detector which simultaneously measures a wavelength range around the analytical wavelength (within a given CCD array), including the background correction wavelength(s ...

PDF 676 KB
Avio Max Series ICP-OES Solid-State RF Generator for Flat Plate Plasma

爱游戏平台注册登录 's Avio® Max series ICP-OES spectrometers feature a free-running solid-state RF generator for Flat Plate plasma, a proprietary technology which generates a transversely symmetrical plasma, replacing previous helical-coil induction. This approach produce ...

PDF 627 KB
Enhancing Cesium Analysis Using the Expanded Wavelength Range of the Avio 220 Max ICP-OES

Traditionally, cesium (Cs) is challenging to measure with ICP-OES, mainly because its two most common wavelengths (455.531 nm and 459.320 nm) are less sensitive. However, the unique Avio® 220 Max hybrid simultaneous ICP-OES features an innovative optical system and detector, which ...

PDF 966 KB
Flat Plate Plasma Technology on the Avio Max Series ICP-OES

A robust and stable plasma is essential when performing analytical analyses by inductively coupled plasma optical emission spectroscopy (ICP-OES). The plasma is traditionally generated by passing argon through a series of concentric quartz tubes (the ICP torch) within a helical, radio frequency ( ...

PDF 739 KB
Multicomponent Spectral Fitting on the Avio Max Series ICP-OES

Baseline and interfering element correction (IEC) are used with ICP optical emission spectrometry to correct analytical signals for contributions from the plasma, the matrix or elements other than the analyte. If the contributions from these components are not corrected accurately, the analytical ...

PDF 287 KB
The Avio 220 Max ICP-OES: A Unique Double-Monochromator Optical System

爱游戏平台注册登录 's Avio® 220 Max ICP-OES delivers outstanding analytical performance thanks to the combination of its double-monochromator optical system and a range of other proprietary technologies that are part of this unique hybrid simultaneous ICP-OES solution.

Read more abou ...

PDF 706 KB
Vertical Dual View on the Avio Max Series ICP-OES

The Avio® Max series ICP-OES incorporates a vertically oriented plasma with complete dual-viewing optics under computer and software control. Its dual view technology optimizes axial and radial plasma viewing to the extended linear dynamic range, measuring high and low concentratio ...

PDF 1 MB

Training