Terbium labeling chelate for creating your own Terbium-labeled biomolecules for use in DELFIA time-resolved fluorescence (TRF) assays. The ITC-activated chelate reacts with free amino groups, such as lysines. The DTPA chelate is more-stable than the N1 chelate.
false falseFor research use only; not for diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption & disposal requirements under European REACH regulations (EC 1907/2006).
DELFIA® Tb-DTPA ITC Chelate is optimized for the terbium labeling of proteins and peptides for use in dissociation-enhanced time resolved fluorometric assays, where especially high chelate stability is required. It is recommended for assays where chelate has to be stable in in vivo conditions (e.g. pharmacokinetics) or assays where high concentrations of competing chelating agents may be present. The isothiocyanato group reacts with free amino groups on the proteins and peptides, forming stable, covalent thiourea bond.
The DTPA-chelates can be used in DELFIA® separation assays where: the concentration of chelating agents is <10 mM, pH>6.5, and the assay temperature is <70°C. They can stand 2 to 3 mmol EDTA when pH is 7.5 or higher. The enhancement time using a DELFIA® shaker is 25 minutes. Isothiocyanate (ITC) activated chelates, react primarily with free lysines on the compound to be labeled.
DELFIA® (dissociation-enhanced lanthanide fluorescence immunoassay) is a time-resolved fluorescence (TRF) intensity technology. Assays are designed to detect the presence of a compound or biomolecule using lanthanide chelate labeled reagents, separating unbound reagent using wash steps. DELFIA assays are flexible, compatible with a variety of plate readers, and, as this is a wash-based technology, compatible with most sample types. The technology is based on fluorescence of lanthanide chelates (Europium, Samarium, and Terbium). The fluorescence decay time of these lanthanide chelate labels is much longer than traditional fluorophores, allowing efficient use of temporal resolution for reduction of autofluorescent background. The large Stokes’ shift (difference between excitation and emission wavelengths) and the narrow emission peaks contribute to increasing signal-to-noise ratio. Sensitivity is further increased because of the dissociation-enhancement principle: the lanthanide chelate is dissociated and a new highly fluorescent chelate is formed into a protective micellar solution. DELFIA lanthanide chelates require this dissociation/enhancement step for fluorescence (induced by addition of DELFIA Enhancement solution, DELFIA Inducer, and DELFIA Enhancer as appropriate to the particular lanthanide chelate).
自動化兼容 | Yes |
---|---|
檢測方法 | Time-Resolved Fluorescence (TRF), DELFIA TRF |
實驗類型 | In vitro |
熒光基團 | Tb-DTPA-ITC |
Format | Microplates |
產品品牌名稱 | DELFIA |
運輸條件 | 藍冰 |
產品尺寸 | 1 mg |
The introduction of enzyme-linked immunosorbent assays (ELISAs) in the early 1970’s offered researchers a non-radiometric immunoassay platform without compromising sensitivity. Over the last 50 years scientists have made huge strides in disease research and drug discovery and a demand for greater ...
DELFIA Tb-DTPA ITC Chelate is optimized for the terbium labeling of proteins and peptides.