NexION 2000S ICP Mass Spectrometer | 爱游戏平台注册登录
爱游戏平台注册登录

Introducing Revvity - Expanding the boundaries of human potential through science

(Revvity was previously affiliated with 爱游戏平台注册登录 , Inc.)

We are now two standalone organizations

Life Sciences & Diagnostics and Analytical & Enterprise Solutions

check quantity

NexION 2000S ICP Mass Spectrometer

爱游戏平台注册登录 ’s NexION® 2000 is the most versatile ICP-MS on the market, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of an instrument that makes it easy to handle any sample matrix, any interference, and any particle size.

爱游戏平台注册登录 received on April 11, 2018 the Application Award from LaborPraxis in the category Bio and Pharma Analysis for the NexION 2000 ICP-MS. We were awarded this prize during analytica 2018 in Munich, Germany, in acknowledgment of a new technique enabling users to quantify the amount of metal in an individual cell for the first time.

Part Number
Model Name
N8150044
NexION 2000B
more
N8150045
NexION 2000C
more
N8150046
NexION 2000P
more
N8150047
NexION 2000S
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Ideal for laboratories testing semiconductors and fine chemicals, the NexION 2000S ICP-MS features:

  • A dedicated SMARTintro High Purity sample-introduction module minimizes contamination and delivers low background equivalent concentrations (BECs))
  • Built-in cold plasma capabilities which, combined with Reaction mode, deliver PPQ detection limits
  • Three quadrupoles, three gas channels, and three modes of operation combine to offer better interference removal, delivering better detection limits/improved data accuracy
  • The industry’s fastest data acquisition speed on the market (100,000 points/sec) to handle any particle size
  • A new solid-state RF generator with revolutionary LumiCoil technology – first ICP-MS RF coil that requires no maintenance or cooling
  • Triple Cone Interface with Quadrupole Ion Deflector, delivering no maintenance beyond the cones
  • Small footprint to minimize bench space
  • Syngistix software provides an intuitive interface that mirrors your workflow, with left-to-right, icon-based navigation that guides you through your analysis. Plus, it’s a cross-platform solution, easing the transition from technique to technique

The NexION 2000 ICP-MS – Triple Quad Power Meets Single Quad Versatility.

Specifications

21 CFR Part 11 Compatible Yes
Depth 69.0 cm
Height 75.0 cm
Model Name NexION 2000S
Portable No
Product Brand Name NexION
Warranty 1 Year
Weight 150.0 kg
Width 81.0 cm
Resources, Events & More
  • All

Application Brief

Arsenic Speciation Analysis in Rice Following Method GB 5009.11-2014 to Ensure Safety

Rice represents a dietary staple for over half of the world's population. However, in recent years, concerns have been raised over the presence of high levels of arsenic (As), where this carcinogenic metalloid can be accumulated at levels far exceeding ambient concentrations. Since China is the w ...

PDF 1 MB
PM10 and PM2.5 Air Pollution Monitoring and Source Apportionment in Asia Using the NexION ICP-MS

Concern about air pollution has been growing rapidly, with most of the focus on gaseous pollutants. Airborne particulates, especially small ones, are rapidly gaining attention due to their impact on human health, as smaller particles can be carried over long distances by wind and penetrate deep i ...

PDF 1 MB

Application Note

A Single Cell-ICP-MS Method to Study the Treatment Efficiency of Algaecide for Toxic Algal Bloom Control

Toxic cyanobacterial blooms were reported worldwide in various aquatic systems, including freshwater rivers, lakes, reservoirs, and eutrophied coastal marine habitats. Cyanobacterial blooms might be caused by a combination of multiple factors, including eutrophication, solar radiation, temperatur ...

PDF 2 MB
Accurate Sizing and Counting of 10 nm Gold Nanoparticles with the NexION ICP-MS

In this work, we demonstrate that 爱游戏平台注册登录 's NexION® 2000 ICP-MS, with its unique RF generator and ion optics, coupled with the Syngistix™ Nano Application Software Module, can be used to accurately measure and characterize NP sizes of 10 nm and smaller, both alone and in a mixture of NPs of vari ...

PDF 2 MB
Analysis of Drinking and Natural Waters with the NexION 2000 ICP-MS

This work has demonstrated the ability of the NexION 2000 ICP-MS to analyze both natural and drinking water samples in Standard (i.e. non-cell) mode, in accordance with U.S. EPA Method 200.8. Accuracy has been demonstrated through the analysis of several reference materials and spike recoveries, wit ...

PDF 1 MB
Analysis of Iron Nanoparticles in Semiconductor Organic Solvents Using Single Particle ICP-MS in Reaction Mode

Metallic contamination in semiconductor products adversely affects device performance. Transition metals are among the most commonly occurring forms of metal contamination – they tend to diffuse through the semiconductor material and aggregate on the surface in various oxide forms, and iron (Fe) ...

PDF 1 MB
Analysis of Single-Walled Carbon Nanotubes with SP-ICP-MS

Measuring the amount of metals in CNTs presents a challenge. High levels can be measured directly in the solid by several techniques, including XRF and TEM, while low-level analysis requires complete digestion of the sample prior to analysis by ICP-OES or ICP-MS.

PDF 555 KB
Analysis of Soils and Waters Following U.S. EPA Method 6020B using the NexION 2000 ICP-MS

Through the years, both industry and analytical instrumentation have advanced. With the development of new chemicals and processes, new pollutants may enter the environment. However, the capabilities of analytical instruments have also increased, allowing the measurement of ever lower levels of envi ...

PDF 2 MB
Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

In semiconductor device fabrication, in an effort to reduce the size of electronic devices and improve the yield of the manufacturing process, chemical-mechanical planarization (CMP) slurries consisting of nanoparticles are now in use. CMP is a process of smoothing surfaces with the combination o ...

PDF 1 MB
Characterization of TiO2 Nanoparticle Release from Fabrics By Single Particle ICP-MS

In the textile industry, the use of titanium dioxide (TiO2) nanoparticles (NPs) is increasing due to their ability to provide UV protection, increase the hydrophilic nature of fabrics, provide antibacterial characteristics, and reduce odors. This work demonstrates the ability of Perkin ...

PDF 516 KB
Comparison of Microsecond vs. Millisecond Dwell Times on Particle Number Concentration Measurements by Single Particle ICP-MS

With the increasing use of nanomaterials in a wide variety of products and processes, the need to measure and characterize them has also grown. Single particle ICP-MS (SP-ICP-MS) was developed specifically for metallic and metal-containing engineered nanoparticles (NPs) and is gaining popularity ...

PDF 924 KB
Compendium - Reliable Methods for Nutritional & Toxic Analysis of Breakfast Foods

Breakfast is an important meal in providing essential nutrients to keep your energy levels up throughout the day. How do we ensure the food and beverages we consume are healthy, nutritious and safe? Following is a collection of application notes highlighting solutions that will help you identify ...

PDF 15 MB
Determination of Impurities in Lithium Materials with the NexION 2000 ICP-MS

With growing concern about the state of the environment, more and more devices are being powered by lithium batteries due to their higher capacities, longer lives, and ability to be recycled, in comparison to conventional batteries. As with all consumer goods, safety and performance are critical ...

PDF 1 MB
Determination of Trace Elements in Eye Drops with the NexION ICP-MS

Eye drops are commonly used medications which are available both over-the-counter and as prescriptions in various forms. Because eye drops are classified as a parenteral medication and have relatively large daily doses, the inorganic components in eye drops must be present at low concentrations. ...

PDF 475 KB
Extraction of Gold Nanoparticles from Fish Larvae and Soils

Gold nanoparticles (AuNPs) are widely used in industrial and medical applications. They are known to form naturally during the weathering of Au-bearing mineral deposits, as well as the transformation of gold nuggets and particles. In freshwater systems, they bioaccumulate in aquatic organisms, as ...

PDF 1 MB
Iron Nanoparticles by SP-ICP-MS: Overcoming Spectral Interferences Using Universal Cell Technology

With the increasing interest in nanoparticles (NPs), various ways of detecting and measuring them are being used. One of the most promising techniques for analyzing metallic NPs is single particle ICP-MS (SP-ICP-MS). This work demonstrates the ability of the NexION® SP-ICP-MS with Univ ...

PDF 1 MB
Monitoring the Fate of Silver Nanoparticles in Seawater Using Single Particle ICP-MS

Single Particle (SP) ICP-MS is an analytical technique that has demonstrated tremendous potential for the measurement and characterization of metal-containing nanoparticles (NPs) in a wide range of sample types, including environmental. One of the most challenging matrices is seawater due to its ...

PDF 1 MB
Multi-Elemental Analysis of Soils Using the NexION ICP-MS

The elemental analysis of soils is of vital importance not only for agriculture, but also from an environmental perspective. Toxic metals enter soil primarily through pollution and can be taken up directly by humans in various manners, potentially causing acute or chronically toxic responses. The ...

PDF 1 MB
New Research Evaluating Cisplatin Uptake in Ovarian Cancer Cells by Single Cell ICP-MS

Cisplatin, carboplatin, and oxaliplatin are the most widely used of platinum-based cancer chemotherapy drugs in the Western world. Cisplatin's effectiveness is due to its ability to bind to the DNA, resulting in DNA-platinum (Pt) adducts, which bend the DNA. The cells must then repair the DNA damage ...

PDF 2 MB
NexION 2000: A Perfect Tool for the Determination of Trace Elements in Blood and Serum

This work demonstrates the ability of 爱游戏平台注册登录 's NexION 2000 ICP-MS to perform accurate, stable analyses of blood and serum samples, leveraging the benefits of the Universal Cell and the ability to use three cell gases in a single method.

PDF 931 KB
Quantification of Nanoparticle Uptake into Cancer Cells using Single Cell ICP-MS

Nanoparticles (NPs) have been of significant interest over the last two decades as they offer attractive benefits for drug delivery to overcome limitations in conventional chemotherapy. Nanoparticles can be engineered to carry both drugs and imaging probes to simultaneously detect and treat cancer. ...

PDF 906 KB
Speciation of Hexavalent Chromium in Children's Toys According to EN 71-3 Category II with the NexSAR HPLC-ICP-MS

Testing for harmful metal(loid)s that may be included in raw materials, processes, paints and additives used in the manufacturing processes of children's toys has been mandated by the regulation EN 71-3. This regulation recommends specific testing methods and maximum allowable concentrations of l ...

PDF 918 KB
Transport of Nanoparticles from Coated Surfaces through Physical Contact

This work investigated the transfer of Ag and CuO nanoparticles from consumer products via simulated dermal contact by using textile wipes as a surrogate using 爱游戏平台注册登录 ’s NexION® ICP-MS single particle analyzer with the unique Syngistix Nano Application software m ...

PDF 1 MB

Brochure

A Complete Portfolio of Grain Testing Solutions

Grains, whether consumed whole or processed, have nutritional and functional requirements and must be safe for consumption, and the only way to ensure grain quality is through rigorous testing. That’s where 爱游戏平台注册登录 come in. Our easy-to-operate, integrated testing and analytical solutions enco ...

PDF 1 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, ...

PDF 3 MB
Comprehensive and Compliant Solutions for Glass Analysis

It’s clear, glass has a variety of uses, from practical to technological to decorative. In particular, float glass is widely used in architecture, automotive, transportation, photovoltaic, and solar industries.

For glass testing labs around the world, we offer highly accurate and tailored ...

PDF 2 MB
Refinery and Natural Gas Analysis Brochure

Oil refineries and natural gas producers around the world require their lab operations to perform large numbers of analyses before their products are used in industries and by consumers. Detection of even the slightest impurities, accurate process control and hydrocarbon distribution analysis is cri ...

PDF 5 MB
USP <232>/<233> & ICH Q3D Capabilities Brochure

The International Conference on Harmonization Guideline for Elemental Impurities Q3D (ICH Q3D) has established maximum permitted daily exposure limits for elemental impurities in pharmaceutical products. In combination with the U.S. Pharmacopeia’s (USP) Chapters <232> and <233> on elemental impur ...

PDF 3 MB

Case Study

NutriControl and 爱游戏平台注册登录 Collaborate to Serve-up Agricultural and Nutritional Analyses

The science and art of creating and maintaining thriving agricultural ecosystems requires cultivating healthy soil, crops and livestock. The safety and efficacy of agricultural chemicals and their uptake into our food supply requires robust, reliable and effective analytical testing on agrochemic ...

PDF 393 KB

Catalog

Atomic Absorption Spectroscopy Consumables Catalog

Download your complete PDF catalog containing all the consumables needed to keep your Atomic Absorption, ICP-OES, and ICP-MS instruments up and running.

PDF 8 MB

Flyer

S20 Series Autosamplers

The S20 series is the next generation of high-performance, robust, and agile autosamplers designed specifically for 爱游戏平台注册登录 ’s spectroscopy platforms - atomic and molecular. The series is comprised of two autosamplers: the S23 with three racks and the S25 with five racks. They are designed to ...

PDF 1 MB
Supporting Sustainability with the NexION ICP-MS Series

Today’s sustainable solutions are opening exciting new ways for businesses to fuel economic growth, while minimizing adverse impact on people and the planet. Laboratories are also working sustainability into their business plans to reduce downtime, waste, and costs – and in many cases, improve th ...

PDF 1 MB

Guide

Atomic Spectroscopy - A Guide to Selecting the Appropriate Technique and System

Atomic spectroscopy is a family of techniques for determining the elemental composition of an analyte by its electromagnetic or mass spectrum. Several analytical techniques are available:

  • Atomic absorption (AA): flame and graphite furnace
  • Inductively coupled plasma optical emis ...

PDF 1 MB
NexION 1000/2000 ICP-MS Preparing Your Laboratory

爱游戏平台注册登录 ICP-MS instruments are complete systems with the exception of the following items which must be provided by the customer: electrical power, exhaust vents, argon gas supplies with approved regulator, cell gas supply with approved regulators

PDF 1 MB
NexION 1000/2000/5000 ICP-MS Consumables & Supplies Guide

Look to 爱游戏平台注册登录 for all of your consumables and supplies for your NexION 1000, 2000, or 5000 ICP-MS system.

PDF 3 MB

Poster

Advanced Solutions for Solar Cells Poster

Download this poster for an all-in-one view of how 爱游戏平台注册登录 instrumentation can answer the analytical needs of the solar market. From R&D of nanomaterials and advanced materials to solar cell component testing including aging and defect analysis - our UV/Vis, DSC, TGA, FT-IR and ICP systems he ...

PDF 1 MB

Regulatory Compliance Certification

Product Certificate - NexION 1000/2000

Product Certificate for the NexION 1000/2000

PDF 98 KB

Technical Note

All Matrix Solution System for NexION ICP-MS Platforms

爱游戏平台注册登录 ’s AMS system provides a number of benefits to simplify analysis of high-matrix samples with theNexION family of ICP-MS instruments. By introducing a flow of argon into the spray chamber neck, the aerosol stream is diluted,allowing for more efficient ionization, fewer matrix effects, a ...

PDF 1 MB
TotalQuant Analysis in NexION ICP Mass Spectrometers

TotalQuant, a software feature unique to 爱游戏平台注册登录 's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information ab ...

PDF 1 MB
Unlocking Carbon-13 with Single Particle ICP-MS: Feasibility Study for Microplastic Detection

Carbon is difficult to measure with ICP-MS because of its high ionization potential and its presence in both the argon used to generate the plasma (primarily in the form of CO2, as an impurity) and in reagents, including acids and water. As a result, extremely high backgrounds exist at ...

PDF 1 MB

Training

Webinars

White Paper

The Determination of Metals in Non-Medical Face Masks

With the onset of the COVID-19 pandemic, the use of face masks by the general public has become a critical personal protective measure to minimize person-to-person transmission. While health care workers use medical or surgical masks, the general population uses non-medical, otherwise known as hy ...

PDF 683 KB
Baidu
map