Feed-, food-, and grain-processing plants across the globe need quick, accurate, and reliable analyses to monitor the quality of incoming raw materials and finished products. The 爱游戏平台注册登录 FT 9700™ is a compact, high-performance, full-wavelength-range Fourier Transform Near Infrared (FT-NIR) spectrometer with a touchscreen interface and low-maintenance design, ideal for food and agricultural product analysis.
false falsePlease enter valid quantity
Please log in to add favorites.
NULL OR EMPTY CART
Analyse all incoming and outgoing deliveries with one analysis in less than 30 seconds. Stop poor quality raw materials at the gate and have full confidence in your products. True laboratory-performance NIR for everyday analysis is now possible with the 爱游戏平台注册登录 FT 9700. It delivers operational simplicity, combining superb performance with low-maintenance design. With integrated touchscreen and PC, the analyzer can be used as a standalone solution, integrated into local networks, or connected to web-based cloud services.
Key features
Our patented technology ensures superior spectra regardless of your application. With an exceptional transferability, advanced electronics, and optimized sensitivity, the FT 9700 analyzer's consistent performance is guaranteed. And with its robust, portable design and incomparable ease-of-use features, it can be deployed wherever it's needed most.
The FT 9700 system is easy to use, so analyses can be performed with minimal training. Using the Results Plus software interface with touchscreen operation, the FT 9700 analyzer offers a simple, modern, intuitive, and productive experience. With our system – reflectance measurements and rotating sample cups during analysis – sample handling is easy.
Expertise in NIR applications
For more than 80 years, 爱游戏平台注册登录 has been providing leading spectroscopy instrumentation and dedicated NIR analyzers for the feed and agricultural industries. With NIR specialist teams around the globe, we're ready to support you with predeveloped as well as custom calibrations. We can also support calibrations provided by external third-party suppliers or developed by users themselves.
The FT 9700 analyzer is also capable of using calibrations based on transferred data from other brand NIR systems using full-wavelength NIR region, FT-NIR, or dispersive scanning monochromator instruments. This means that the NIR databases and calibrations do not have to be recreated when using the new FT 9700 NIR platform.
Specifications
Analysis time | <30 seconds |
---|---|
Measurement mode | Up-view reflection or transflectance |
Sample types | Ground or unground grains and pellets, powders, meals, and more |
Sample volume | Flexible, 5 ml to 150 ml, depending on sample type |
Display | 12-in. color touchscreen |
Operating system | Microsoft Windows® 10 Enterprise |
Language | Multiple languages, including English, Chinese, Thai, Russian, and more |
Interface | USB ports and Ethernet |
Operating temperature range | 5 °C to 40 °C |
Wavelength range | 700 nm to 2500 nm |
Detector | Indium gallium arsenide (InGaAs) |
Wavelength accuracy | <0.03 nm at 1670 nm |
Dimensions | (H) 550 mm x (W) 460 mm x (D) 410 mm (including touchscreen) |
Power requirements | 100 - 230 V, 50/60 Hz |
Weight | 26 kg |
Moisture, starch, protein and fat are important parameters to consider when assessing the quality of corn. The specialty end uses for corn often require these parameters to fall within a certain range. More worryingly, particularly high or low concentrations of these parameters could lead to heal ...
Major nutritional components of soymeal, such as moisture, protein, and fat, can have a key influence on the animals' growth and, ultimately, the overall profits of farmers. Therefore, accurate analysis of these nutritional parameters of soymeal is highly important to allow producers to ensure th ...
Harvested wheat is typically milled into flour which can then be used to make a wide range of foods, such as bread and pasta or used as raw material in feed production. Moisture and protein are key parameters for evaluating quality of a wheat sample to be used in flour milling or for setting up f ...
Food companies operate in highly diverse and complex supply chains that are tightly regulated across the globe. You’re constantly challenged – from compliance with hazard analysis critical control points (HACCP) and food safety plans to ensuring nutritional and compositional quality across your o ...
Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, ...
Food laboratories across the globe need quick, accurate, reliable analyses to monitor the quality of products and incoming raw materials. Introducing the 爱游戏平台注册登录 FT 9700™ – the compact, high-performance full-wavelength range FT-NIR spectrometer suited for a wide array of appl ...
Everyone knows the value of data these days. The value of NIR calibration data (spectral data, it’s associated reference chemistry, that spans multiple crop years and production runs) is often a major inhibiting factor to upgrading old spectrometers or changing from an ill-suited vendor. This sho ...
Product Certificate for the FT 9700 Bench-top FT-NIR instrument