爱游戏平台注册登录
check quantity

LANCE Eu-W1024-ITC Chelate and Eu Standard, 0.2 mg

Europium labeling chelate for creating your own Europium-labeled biomolecules for use in LANCE TR-FRET assays. The ITC-activated chelate reacts primarily with free amino groups, such as lysines.

貨號 AD0096
Request Technical Support

請輸入有效數量

請登錄以添加收藏夾。

購物車為空

For research use only; not for diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption & disposal requirements under European REACH regulations (EC 1907/2006).

詳細信息

LANCE® Eu-W1024-ITC Chelate is optimized for the labeling of proteins and peptides at least one primary aliphatic amino group. The labeled compound can be used in homogeneous time-resolved fluorescence resonance energy transfer (TR-FRET) assays (LANCE® assays).

  • Isothiocyanate (ITC) activated chelates react primarily with free amine groups such as ones a N-terminus of protein or lysine residues. 
  • LANCE® W1024 Series chelates are preferred in most HTS applications due to their lower fluorescent background in TR-FRET assays. 
  • For most LANCE™ applications the W1024 series of Eu chelates with active group can be used. Usable pH range 5-11. Under neutral conditions W1024 remains stable in EDTA concentrations up to 20 mmol/L. Allophycocyanin (APC)- or ULight-labeled compounds can be used as acceptors for LANCE® TR-FRET assays.

LANCE® (Lanthanide chelate excite) and LANCE® Ultra are our TR-FRET (time-resolved fluorescence resonance energy transfer), homogeneous (no wash) technologies. One molecule of interest is labeled with a donor fluorophore (a LANCE Europium chelate) and the second molecule is labeled with an acceptor fluorophore [ULight™ dye, allophycocyanin (APC)]. Upon excitation at 320 or 340 nm, energy can be transferred from the donor Europium chelate to the acceptor fluorophore if sufficiently close for FRET (~10 nm). This results in the emission of light at 665 nm (for ULight dye and APC).

規格

自動化兼容 Yes
檢測方法 Time-Resolved Fluorescence (TRF), TR-FRET
實驗類型 In vitro
熒光基團 Eu-W1024-ITC
Format Microplates
產品品牌名稱 LANCE
運輸條件 藍冰
產品尺寸 0.2 mg
資源
  • 所有

產品手冊

應用簡報

Eight Limitations of ELISA and How to Overcome Them Using Alternative Technologies

The introduction of enzyme-linked immunosorbent assays (ELISAs) in the early 1970’s offered researchers a non-radiometric immunoassay platform without compromising sensitivity. Over the last 50 years scientists have made huge strides in disease research and drug discovery and a demand for greater ...

PDF 1 MB
Baidu
map