LANCE Ultra total AKT1 kits are designed for the detection of total AKT1 (phosphorylated and unphosphorylated) in cell lysates using a simple, homogeneous LANCE Ultra assay (no wash steps). This assay can be used as a normalization assay for phospho-AKT1, and is compatible with both adherent and suspension cells.
false falseFor research use only; not for diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption & disposal requirements under European REACH regulations (EC 1907/2006).
Please note control lysates are NOT included in kits. Control lysates are sold separately, catalog number TRF4013S.
Formats:
LANCE® and LANCE® (Lanthanide chelate excite) Ultra are homogeneous (no wash) TR-FRET (time-resolved fluorescence resonance energy transfer) technologies. One antibody of interest is labeled with a donor fluorophore (a LANCE Europium chelate) and the second antibody is labeled with an acceptor fluorophore [ULight™ dye]. Upon excitation at 320 or 340 nm, energy can be transferred from the donor Europium chelate to the acceptor fluorophore if sufficiently close for FRET (~10 nm). This results in the emission of light at 665 nm. Data are represented as ratiometric (665/615 nm X 10,000).
AKT, also known as protein kinase B, is an important regulator of numerous cellular processes including cell survival, glucose metabolism, transcription, and apoptosis. AKT has three closely related isoforms (AKT1, AKT2, and AKT3), and these isoforms have been shown to act on both common and unique downstream substrates. AKT activation can be induced by a number of stimuli, whereby AKT is transported to membrane for phosphorylation. Activation occurs upon AKT phosphorylation of Thr308 by PDK1 and of Ser473 by mTORC2. AKT subsequently dissociates from the membrane and phosphorylates targets both in the cytoplasm, as well as, the cell nucleus. Deregulation of AKT has been implicated in a number of disease states including cancer, cardiovascular disease, and diabetes.
分析途徑 | PI3K/Akt/mTOR |
---|---|
檢測目標 | Akt1 |
檢測目標類 | Protein |
自動化兼容 | Yes |
檢測方法 | Time-Resolved Fluorescence (TRF), TR-FRET |
產品品牌名稱 | LANCE Ultra |
運輸條件 | 藍冰 |
治療領域 | Neuroscience, Cardiovascular, Metabolic |
產品尺寸 | 10,000 Assay Points |
G protein coupled-receptors (GPCRs) are one of the most intensively studied drug targets, with up to one-third of all marketed therapeutics acting by binding to GPCRs. Therapies that target GPCRs include both agonist and antagonists that are used in the treatment of disease in nearly every major ...
The introduction of enzyme-linked immunosorbent assays (ELISAs) in the early 1970’s offered researchers a non-radiometric immunoassay platform without compromising sensitivity. Over the last 50 years scientists have made huge strides in disease research and drug discovery and a demand for greater ...