Phospho-SLP-76 (Ser376) LANCE Ultra TR-FRET Cellular Detection Kit, 10,000 Assay Points

LANCE Ultra phospho-SLP-76 (Ser376) kits are designed for the detection of SLP76 (phosphorylated at S376) in cell lysates using a simple, homogeneous LANCE Ultra assay (no wash steps). This assay is compatible with both adherent and suspension cells.

For research use only; not for diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption & disposal requirements under European REACH regulations (EC 1907/2006).

貨號
產品尺寸
TRF4010C
500 Assay Points
更多
TRF4010M
10,000 Assay Points
更多
Request Technical Support

請輸入有效數量

請登錄以添加收藏夾。

購物車為空

詳細信息

Please note control lysates are NOT included in kits. Control lysates are sold separately, catalog number TRF4010S.

Formats:

  • Our 500 assay point kit allows you to run 500 wells in 384-well format, using a 20 µL reaction volume.
  • Our 10,000 assay point kit allows you to run 10,000 wells in 384-well format, using a 20 µL reaction volume.

LANCE® and LANCE® (Lanthanide chelate excite) Ultra are homogeneous (no wash) TR-FRET (time-resolved fluorescence resonance energy transfer) technologies. One antibody of interest is labeled with a donor fluorophore (a LANCE Europium chelate) and the second antibody is labeled with an acceptor fluorophore [ULight™ dye]. Upon excitation at 320 or 340 nm, energy can be transferred from the donor Europium chelate to the acceptor fluorophore if sufficiently close for FRET (~10 nm). This results in the emission of light at 665 nm. Data are represented as ratiometric (665/615 nm X 10,000).

Lymphocyte cytosolic protein (SLP-76) is required for T-cell activation and has been implicated in a number of signaling pathways. SLP76 is phosphorylated at Ser376 by HPK1, and this phosphorylation leads to a decrease in T-cell receptor signaling.

規格

檢測目標 SLP-76
檢測目標類 Phosphoprotein
自動化兼容 Yes
檢測方法 Time-Resolved Fluorescence (TRF), TR-FRET
產品品牌名稱 LANCE Ultra
運輸條件 藍冰
治療領域 Autoimmunity, Inflammation, Immuno-oncology
產品尺寸 10,000 Assay Points
資源
  • 所有

產品手冊

應用簡報

Eight Limitations of ELISA and How to Overcome Them Using Alternative Technologies

The introduction of enzyme-linked immunosorbent assays (ELISAs) in the early 1970’s offered researchers a non-radiometric immunoassay platform without compromising sensitivity. Over the last 50 years scientists have made huge strides in disease research and drug discovery and a demand for greater ...