NexION 5000 Multi-Quadrupole ICP Mass Spectrometer

NexION 5000是業界首款多重四極杆ICP-MS,由四組四極杆組成。其創新設計達到和超過如半導體、生物監測和其他應用領域嚴苛的痕量和超痕量元素檢測要求。NexION 5000性能超越了傳統的三重四極杆技術,提供極低的背景等效濃度(在高溫熱等離子字體中,BECs<1 ppt)和出色的檢測極限,確保了結果的精度和可重現性。NexION 5000 ICP-MS具有:

  • 卓越的幹擾消除能力
  • 出色的背景等效濃度(BECs)
  • 無與倫比的基體耐受性
  • 符合SEMI S2/S8法規和安規要求

貨號
型號名稱
技術類型
N8160010
NexION 5000 Cleanroom ICP-MS
Multi-Quad ICP-MS for Cleanroom Applications
更多
N8160009
NexION 5000 Non-Cleanroom ICP-MS
Multi-Quad ICP-MS for Non-Cleanroom Applications
更多
Request Technical Support

請輸入有效數量

請登錄以添加收藏夾。

購物車為空

詳細信息

The NexION 5000 Non-Cleanroom ICP-MS is highly recommended for applications which do not require the use of a cleanroom, but which still benefit from the unmatched sensitivity and interference removal capabilities of the NexION 5000 series. It features a host of new and proprietary technologies that deliver outstanding detection limits, astounding accuracy, excellent repeatability and the long-term stability required by your applications:

  • Four quadrupoles:
    • First: Quadrupole Ion Deflector (Q0) directs ions to the entrance of the first mass filter
    • Second: Transmission Analyzer Quadrupole 1 (Q1, full-sized for <0.7 amu mass resolution), acts as a mass filter or as an ion guide to direct ions to the Quadrupole Universal Cell
    • Third: Quadrupole Universal Cell (Q2), empowered by dynamic bandpass tuning, prevents side reactions with residual reaction gases in the cell
    • Fourth: Transmission Analyzer Quadrupole 2 (Q3, full-sized for <0.7 amu mass resolution), acts as a mass filter or as an ion guide to direct ions to the detector
  • Extended Dynamic Range (EDR) increases linear dynamic range to 1012, allowing the accurate analysis of both high- and low-concentration analytes in a single analytical run, resulting in fewer re-runs
  • Low maintenance for greater uptime:
    • Triple Cone Interface with patent-pending OmniRing combined with Quadrupole Ion Deflector deliver no maintenance beyond cones, for continual operation and improved stability
    • 34 MHz free-running RF generator offers trouble-free user experience - the plasma is generated by the unique LumiCoil RF load coil, which is air cooled (does not require water or gas cooling), so maintenance-free, eliminating need to replace plasma load coils
  • External status lighting provides easy visibility of state of analysis, optimizing efficiencies
  • Syngistix for ICP-MS software (v. 3.0 or higher) brings together the power of the triple-quad ion optics with automated startup, optimization, batch analysis and shutdown, user-friendly workflows, and more in a contemporary user interface

規格

深度 85.0 cm
高度 85.0 cm
型號名稱 NexION 5000 Non-Cleanroom ICP-MS
產品品牌名稱 NexION
技術類型 Multi-Quad ICP-MS for Non-Cleanroom Applications
重量 191.0 kg
寬度 114.0 cm
資源
  • 所有

網絡研討會

網絡研討會

產品手冊

Comprehensive Forensic Analysis Solutions

This brochure provides a simple guide to the analytical solutions and supporting services we provide for forensics and toxicology laboratories.

We know it's not as simple as it seems in the movies, on television, or in the latest potboiler: forensic science is an exacting science, driven by ...

PDF 1 MB
NexION 5000 Multi-Quadrupole ICP-MS - Interactive Brochure

In the fast-paced analytical world, accurate and reproducible results are essential to guaranteeing quality and ensuring safety. What many industries have in common is the need for trace-element analysis with superior interference removal, extremely low detection limits, and outstanding backgroun ...

PDF 2 MB
A Complete Portfolio of Grain Testing Solutions

Grains, whether consumed whole or processed, have nutritional and functional requirements and must be safe for consumption, and the only way to ensure grain quality is through rigorous testing. That’s where 爱游戏平台注册登录 come in. Our easy-to-operate, integrated testing and analytical solutions enco ...

PDF 1 MB

產品說明

NexION 5000 Multi-Quadrupole ICP-MS

The NexION® 5000 is a multi-quadrupole-based ICP-MS instrument engineered to remove the most complex interferences, ideal for multi-element analysis applications requiring ultra-trace-level detection. Download this product note to discover all of its innovative features.

PDF 760 KB

單頁

NexION 5000 ICP-MS – Innovation Recognized

Perfect for your most challenging applications, the cutting-edge, multi-award-winning NexION® 5000 Multi-Quadrupole ICP-MS is the industry’s first and only four-quadrupole ICP-MS instrument – taking performance well beyond everyday triple-quad technology. And the scientific community i ...

PDF 204 KB
Supporting Sustainability with the NexION ICP-MS Series

Today’s sustainable solutions are opening exciting new ways for businesses to fuel economic growth, while minimizing adverse impact on people and the planet. Laboratories are also working sustainability into their business plans to reduce downtime, waste, and costs – and in many cases, improve th ...

PDF 1 MB
LaserTRAX-NexION 5000 ICP-MS - Your fully automated sample introduction, laser ablation-ICP-MS solution

Driven by the increasing need for faster sample turnaround times, less analyst error, and more sustainable operations, today’s testing labs conducting elemental analyses of geological samples rely on direct solid sampling techniques. In response to these needs, we’ve partnered with Elemental Scie ...

PDF 814 KB

應用文獻

Determination of Bromine in Ultra-High-Purity Copper using the NexION 5000 ICP-MS

Copper (Cu) is widely used due to its high electrical and thermal conductivity, strong corrosion resistance, excellent workability and moderate strength. It is one of the few metals used most commonly in its pure form, and ultra-pure copper specifically is the standard material used in the bondin ...

PDF 1 MB
Direct Determination of Rare Earth Impurities in High-Purity Gadolinium Oxide with the NexION 5000 ICP-MS

Gadolinium (Gd) is commonly used in the production of magnetic compounds. Another application is in Mg-Gd-based alloys, which are used primarily for their excellent corrosion-resistance properties, and it is for this reason that they can be used in many other applications which require high-stren ...

PDF 1 MB
Direct Trace-Element Analysis in Cell Culture Media and Raw Materials with the NexION 5000 ICP-MS

Raw material preparation and formulation is a known source of elemental content and variation in cell culture media. Other sources of trace metal concentrations and variability include the leaching of trace metals from bioreactors, preparation vessels and storage containers. Quality control in ce ...

PDF 756 KB
Direct Determination of Rare Earth Impurities in High-Purity Neodymium Oxide with the NexION 5000 ICP-MS

Since the purity of the rare earth elements (REEs) governs their efficacy and the price, it is of great interest to produce ultra-high purity rare earth oxides. Neodymium oxide (Nd2O3) is one such REE and is mainly used as a colorant for glass and ceramics, a raw material fo ...

PDF 1 MB
Direct Determination of Trace Rare Earth Impurities in High-Purity Europium Oxide using the NexION 5000 ICP-MS

Rare earth elements (REEs) exhibit many optical, electrical, and magnetic properties, and therefore play an irreplaceable role in high-tech photoelectromagnetic materials. At present, the widely used color TV phosphors, Ni-H batteries, high-performance magnetic materials, etc. are all examples of ...

PDF 1 MB
Analysis of Blood Using NexION 5000 ICP-MS

For many years, inductively coupled plasma mass spectrometry (ICP-MS) has been the tool of choice for the trace analysis of elements like lead (Pb), arsenic (As), mercury (Hg), and copper (Cu) in bodily fluids such as urine, blood, serum and saliva, as well as in tissues.

Blood and serum ar ...

PDF 1 MB
Direct Determination of Trace Rare Earth Impurities in High-Purity Praseodymium Oxide with the NexION 5000 ICP-MS

Rare earth elements (REEs) are often referred to as "industrial vitamins", as they are used in a variety of traditional industrial fields as well as in new materials. A particularly important application of some REEs, for example high-purity praseodymium oxide (Pr6O11), is t ...

PDF 1 MB
Lead and Strontium Isotope Ratio Analysis Using the NexION 5000 ICP-MS

Isotope ratio measurements are used in many application fields, such as nuclear, geological, geochronological dating, clinical, and others. Depending on the industry, there is interest in measuring natural, depleted, or enriched isotope ratios and exact abundances of all isotopes for the element( ...

PDF 665 KB
Direct Determination of Rare Earth Impurities in High-Purity Ytterbium Oxide with the NexION 5000 ICP-MS

Rare earth elements (REEs) are crucial components in many advanced materials for industrial use, as well as consumer electronics. As the properties and prices of REEs are dependent on their purity, it is of great interest to produce rare earth oxides of high purity. High-purity ytterbium oxide (Y ...

PDF 1 MB
High Throughput LA-ICP-MS Analysis of REE Ore Samples Using the LaserTRAX-NexION 5000 Integrated Solution

Rare earth elements (REEs) are increasingly important in the production of high-specification electronic devices, and their discovery requires a rapid and cost-effective screening of survey samples for REE content, as greater resolution of a survey area would necessitate analysis of hundreds/thou ...

PDF 1 MB
Direct Analysis of Trace Elements in Open-Ocean Seawater using the NexION 5000 ICP-MS

Due to high total dissolved solids (TDS), seawater is considered one of the most difficult matrices to analyze for the presence of heavy metals and other trace elements. Plus, trace elements in open-ocean seawater are even lower than in coastal areas, thus are more challenging to accurately measu ...

PDF 1 MB
Determination of Rare Earth Impurities in High-Purity CeO2 with NexION 5000 ICP-MS per Chinese Method GB/T 18115.2-2020

With the development of optoelectronic communication technology, the demand for radio and television materials is increasing, especially that of high-purity rare earths. As such, rare earth elements (REEs) are often referred to as “industrial vitamins”. In these applications, the purity of the RE ...

PDF 278 KB
Determination of Toxic and Other Trace Elements in Baby Foods Using the NexION ICP-MS

For many children around the globe, commercial baby foods are the main source of nutrients and energy, and therefore their quality and safety are critical and must be monitored. In March 2021, the U.S. House of Representatives introduced the “Baby Food Safety Act of 2021” to regulate the presence ...

PDF 699 KB
Determination of Selenium Species in Drinking Water by HPLC-ICP-MS

Selenium (Se) is an essential element at trace levels, toxic at higher levels, and exists in several oxidation states in a variety of inorganic and organic compounds. Consequently, the chemistry of selenium is complex in both the environment and biota.

For the determination of selenium spec ...

PDF 907 KB
Measurement of Impurities in High-Purity Copper Concentrate using the NexION 5000 ICP-MS

Most of the copper (Cu) concentrates produced globally contain some impurities, which can affect the price as copper concentrates containing high levels of impurities are not accepted by some smelters. To permit treatment and to maximize the value of a Cu concentrate, the levels of impurities in ...

PDF 1 MB

應用簡報

Determination of Heavy Metals in Cassava Flours Using NexION ICP-MS Following U.S. FDA EAM 4.7 Method

Cassava is a root vegetable and a major source of calories and carbohydrates in many countries around the globe. As one of the most important staple crops, its levels of harmful chemicals and pathogens are strictly controlled – these include organic chemicals and heavy metals. Metals, such as cad ...

PDF 1 MB
Determination of Organotin in Tap Water by HPLC-ICP-MS in Accordance with Chinese Method HJ 1074-2019

Organotin compounds are widely used across industry and agriculture, resulting in widespread pollution of various environmental media, including potable water. Among these compounds are tributyltin (TBT), triphenyltin (TPT), dibutyltin (DBT), and diphenyltin (DPT), in the following order of persi ...

PDF 506 KB
PM10 and PM2.5 Air Pollution Monitoring and Source Apportionment in Asia Using the NexION ICP-MS

Concern about air pollution has been growing rapidly, with most of the focus on gaseous pollutants. Airborne particulates, especially small ones, are rapidly gaining attention due to their impact on human health, as smaller particles can be carried over long distances by wind and penetrate deep i ...

PDF 1 MB

技術說明

Interferences in ICP-MS: Do we still have to worry about them?

Interferences will always occur in ICP-MS and need to be dealt with. However, the NexION® 5000 multi-quadrupole ICP-MS with quadrupole Universal Cell is able to effectively and reproducibly remove spectral interferences leading to improved accuracy, repeatability and reproducibilit ...

PDF 1 MB
Novel Interference Removal Opportunities with the NexION 5000 ICP-MS

The NexION® 5000 ICP-MS, with multi-quadrupole technology and Universal Cell, is able to take full advantage of element reactivity with 100% pure gases by analyzing them as cluster ions at higher masses where no interferences reside, and the background is clean. The Universal Cell, ...

PDF 2 MB
All Matrix Solution System for NexION ICP-MS Platforms

爱游戏平台注册登录 ’s AMS system provides a number of benefits to simplify analysis of high-matrix samples with theNexION family of ICP-MS instruments. By introducing a flow of argon into the spray chamber neck, the aerosol stream is diluted,allowing for more efficient ionization, fewer matrix effects, a ...

PDF 1 MB
Advantages of a Novel Plasma Generator for the NexION 1000/2000/5000 ICP-MS Systems

Unlike other ICP-MS systems on the market that utilize conventional 40-MHz or 27-MHz commercially available generators which are typically customized and modified to work with ICP-MS instruments, the NexION® 1000/2000/5000 ICP-MS systems feature a 34-MHz frequency free-running RF g ...

PDF 986 KB
Unlocking Carbon-13 with Single Particle ICP-MS: Feasibility Study for Microplastic Detection

Carbon is difficult to measure with ICP-MS because of its high ionization potential and its presence in both the argon used to generate the plasma (primarily in the form of CO2, as an impurity) and in reagents, including acids and water. As a result, extremely high backgrounds exist at ...

PDF 1 MB
TotalQuant Analysis in NexION ICP Mass Spectrometers

TotalQuant, a software feature unique to 爱游戏平台注册登录 's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information ab ...

PDF 1 MB
Advantages of a Novel Interface Design for NexION 5000 ICP-MS

The novel design of the second-generation Triple Cone Interface with patent-pending OmniRing was developed specifically for the NexION® 5000 multi-quadrupole ICP-MS with both sensitivity and stability in mind. It builds on the Triple Cone Interface geometry of the ...

PDF 1 MB

指南

原子光譜將指導您選擇合適的技術和係統

本指南概述了最常用的原子光譜技術,並提供了所需信息,能夠幫助您選擇最適合您個人需求的應用。

PDF 1 MB
NexION 5000 ICP-MS Preparing Your Lab

This document provides information to assist in preparing your laboratory for the 爱游戏平台注册登录 NexION® 5000 ICP-MS system prior to instrument delivery and installation.

PDF 1 MB
NexION 1000/2000/5000 ICP-MS Consumables & Supplies Guide

Look to 爱游戏平台注册登录 for all of your consumables and supplies for your NexION 1000, 2000, or 5000 ICP-MS system.

PDF 3 MB
.
Baidu
map