兩家獨立企業由此誕生
生命科學與診斷 & 分析和企業服務

×
×

兩家獨立企業由此誕生

  • 生命科學與診斷業務

    專注於生命科學和診斷業務的高增長型公司,推動科學家和醫療衛生專業人士的研究、發現和檢測,助力打造更健康的世界

  • 分析和企業服務業務

    我們專注於提供全方位的分析和企業服務解決方案,包括領先的OneSource實驗室服務,加速您的科學研究進程

OptiPlate-384, White Opaque 384-well Microplate, Case 50 | 爱游戏平台注册登录
爱游戏平台注册登录
check quantity

OptiPlate-384, White Opaque 384-well Microplate, Case 50

384-well microplate for use in time-resolved fluorescence, luminescence, Alpha, and radiometric assays. This OptiPlate™ is white and made of polystyrene.

貨號
產品尺寸
6007290
Case of 50
更多
6007299
Case of 200
更多
Request Technical Support

請輸入有效數量

請登錄以添加收藏夾。

購物車為空

詳細信息

The OptiPlate is one of the most versatile microplates offered by 爱游戏平台注册登录 , used in many different applications, assays, and instruments. The optimized well design and high quality plastics provides low background and crosstalk.

OptiPlates are uniquely engineered to be the same height for 96-, 384-, and 1536-well plates, and with extraordinary well flatness for ease in automation.

Leveraging years of assay and instrument experience in plate detection, 爱游戏平台注册登录 designs better microplates for better performance that guarantees better results for all 爱游戏平台注册登录 applications.

Packaging Notes:

  • Cases of 50 are packaged as 2 sleeves of 25 plates each. Each sleeve as 5 wraps with 5 plates.
  • Cases of 100 are packaged as 4 sleeves of 25 plates each.
  • Cases of 200 are packaged as 8 sleeves of 25 plates each. Each sleeve as 5 wraps with 5 plates.

Well Plate Dimensions

Well format: 384-well

Number of Rows 16
Number of Columns 24
Well volume 105 µL
Recommended working volume 24 µL – 90 µL
Height (mm) 14.35
Length (mm) 127.76
Width (mm) 85.47
Well diameter (mm) 3.65
Well depth (mm) 10.4
A1 to top offset (mm) 9
A1 to side offset (mm) 12.1
Well-to-well spacing (mm) 4.5

規格

自動化兼容 Yes
塗層處理 Untreated
顏色 White
檢測方法 Luminescence, Alpha, Time-Resolved Fluorescence (TRF & TR-FRET), Radiometric
Format Microplates
材料 Polystyrene
產品品牌名稱 OptiPlate
運輸條件 環境
Sterile No
產品尺寸 Case of 50
阱數量 384 well plate
資源
  • 所有

應用文獻

Quantify Low Abundant mIL-17A Homodimer in Mouse Serum and Plasma

Measuring low levels of biomarkers in complex biological samples such as serum and plasma is always a challenge. This is further complicated by the low sample volumes collected from mice, which are widely used in the early stages of drug discovery and development.

This application note demo ...

PDF 1 MB
Utilizing AlphaLISA Technology to Screen for Inhibitors of the CTLA-4 Immune Checkpoint

Immune checkpoints serve a critical role in the immune system to prevent autoimmunity and manage the degree and duration of an immune response. Cytotoxic T-Lymphocyte-associated protein 4 (CTLA-4 or CD152) is an inhibitory transmembrane protein involved in an immune checkpoint of significant inte ...

PDF 1 MB
Measuring PD-L1 Expression in Breast Cancer Cell Lines with AlphaLISA

Too many candidates, too little time. The lack of robust, rapid, high-throughput assays to identify and qualify potential therapeutic targets in areas such as cancer research continues to cost valuable time. What if you could increase assay throughput without compromising sensitivity, obtain more da ...

PDF 4 MB

指南

Guide to Selecting a Microplate

Your specific applications deserve the best microplates!

For a researcher, the need to select the most suitable application-specific microplates is critical. Format, color, and surface properties are among the different features that can impact your assay performances and the quality of you ...

PDF 765 KB
Baidu