QSight LX50 Solvent Delivery Module | 爱游戏平台注册登录
爱游戏平台注册登录
check quantity

QSight LX50 Solvent Delivery Module

Our QSight® LX50 UHPLC integrates seamlessly to our QSight Triple Quad LC/MS/MS and its Simplicity software to deliver the highest levels of performance from sample handling through data collection and reporting. The system includes three key technologies that help optimize your workflow and enable high productivity.

Part Number N2991000
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

For the QSight triple quad LC/MS/MS, we’ve paired the industry’s most flexible mass spectrometer with the equally capable QSight LX50 UHPLC system, delivering all the sensitivity and specificity you need for demanding applications such as pesticide-residue and nutritional-component analysis. And with its robust design and carryover-elimination capabilities, the system is perfect for a host of other applications in the food and environmental arenas.

Resources, Events & More
  • All

Application Note

A New, Sensitive Method for Lignan Metabolite Detection of Flaxseed-Fed Mice Using LC/MS/MS

A New, Sensitive Method for Lignan Metabolite Detection of Flaxseed-Fed Mice Using LC/MS/MS

PDF 1 MB
A Single Cannabis Method to Meet California Pesticide and Mycotoxin Residues Regulatory Requirements

Testing for the levels of pesticide and mycotoxins in cannabis is important to ensure consumer safety and quality control. In this work, the 爱游戏平台注册登录 application development team analyzed all 66 pesticides (including very hydrophobic and chlorinated pesticides typically analyzed by GC-MS/MS) and ...

PDF 2 MB
Analysis of Acrylamide in Potato Chips by Isotopically Standard Addition UHPLC-MS/MS

Acrylamide is a probable carcinogen organic compound that is found in some foods that are cooked at elevated temperatures. It’s origins are due to the condensation of the amino acid asparagine and glucose as part of Maillard reaction. In 2002, Acrylamide was found to be present in french fries an ...

PDF 1 MB
Analysis of Aflatoxins by UHPLC

Aflatoxin B1 is considered to be the most genotoxic of the mycotoxins, and, when ingested by cows, is converted to aflatoxin M1 which has been shown to cause liver cancer in certain animals.

PDF 1 MB
Analysis of Multi-Residue Pesticides in Rice by LC/MS/MS

Due to the large number of pesticides potentially used in rice production, the use of multi-residue methods capable of determining many pesticides in one single run is the most efficient approach. In this study, a fast, sensitive and selective multiresidue method has been developed for analysis o ...

PDF 1 MB
Analysis of Mycotoxins in Multi-Grain and Corn Cereals

Mycotoxins produced by fungi as toxic secondary metabolites, leave grains, maize and cereals particularly vulnerable. With this in mind, and considering that an estimated 25% of all crops show some signs of mycotoxin contamination, many countries have established regulatory guidelines for maximum ...

PDF 991 KB
Analysis of PFAS in Drinking Water with EPA Method 537.1 Using QSight UHPLC/MS/MS

Perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) are the two most extensively produced and studied of the per- and polyfluoroalkyl substances (PFAS) owing to their stability in the environment and toxicity to humans and wildlife. The United States Environmental Protection Age ...

PDF 1 MB
Analysis of Per- and Polyfluoroalkyl Substances by EPA Method 8327 Using the QSight 220 UHPLC/MS/MS

Per- and polyfluoroalkyl substances (PFAS) are man-made carbon-chain based compounds that have been widely used in commercial and industrial products such as fire-fighting foams, water proofing treatments for clothing and furniture, nonstick cookware, and paper. PFAS’ are thermally and chemically ...

PDF 1 MB
Analysis of Pesticide Residues in Cannabis Regulated by Oregon State Using LC/MS/MS

Liquid chromatography-tandem mass spectrometry (LC/MS/MS) has become the method of choice for pesticide. The state of Oregon has issued regulatory limits for 59 pesticide residues in both cannabis flower and concentrates, while other states have come up with their own lists of pesticide residues ...

PDF 1 MB
Analysis of Target Pesticide Residues in Berries with LC/MS/MS Coupled with a QuEChERS Sample Prep

Analysis of target pesticide residues in berries using a unique laminar flow UHPLC-ESI-MS/MS

PDF 1 MB
Analysis of Water-Soluble Vitamins in Infant Formula by UHPLC-MS MS

Water-soluble vitamins (WSV), comprised primarily of the vitamin B complex, are essential ingredients in many foods, particularly in infant formulas. When analyzing fortified foods, this can be particularly challenging due to the wide range in concentration of vitamins, in keeping with daily allowan ...

PDF 1 MB
Analysis of illegal dyes in Chili Spices via UHPLC-MS/MS

Since 2003 the usage of azo and non-azo dyes for food coloring has been declared as illegal by many of the food international authorities across the globe. That is because these substances such as Sudan I,II,III,IV and Rhodamine B, are potentially carcinogens and genotoxin in nature. As of now, n ...

PDF 4 MB
Detection of Fipronil and Metabolites in Eggs by LC-MS/MS

Fipronil is a broad-spectrum phenylpyrazole insecticide almost used to protect corps from insects but also to treat lice and ticks in chickens. The U.S. EPA classified fipronil as Group C, possible human carcinogen, therefore International organizations defined admissible limits for the fipronil ...

PDF 719 KB
Determination of Polycyclic Aromatic Hydrocarbons in Seafood by UHPLC- MS/MS

Polycyclic aromatic hydrocarbons (PAHs) can contaminate foods during smoking, heating, and drying processes that allow combustion products to come into direct contact with food. They can also enter food supply chains through contaminated air and water, and accumulate in various food chains. Regulati ...

PDF 1 MB
Determination of Sulfonamides in Honey

In apiculture, sulfonamides are the most commonly used antibiotics to treat American and European Foulbrood, a type of disease that infects bees. This application note demonstrates how QSight 200 System can provides a very sensitive and robust platform for the analysis of sulfonamides in honey.

PDF 1 MB
Determination of Sulfonamides in milk by Ultra-Performance Liquid Chromatography coupled with Tandem Mass Spectrometry (QSight™)

Antibiotics are used in dairy cattle for different treatments, but it leads to accumulation of these residues in milk. Presence of such residues in human food can be responsible for allergic reactions, toxic effects and develops resistant strains of bacteria. To protect consumers, regulatory agen ...

PDF 579 KB
PDF 1 MB
Direct Analysis of Glyphosate and Similar Polar Pesticides in Oatmeal by UHPLC-MS/MS

Glyphosate is a very polar compound with high solubility in water and low solubility in most organic solvents and, as such, requires methods based on derivatization which are labor-intensive and time consuming. The present work shows a 12 minute LC-MS/MS method with an amino-based column to analy ...

PDF 1 MB
Estimation of 136 pesticide residue in Black Pepper using QuEChERS extraction technique and QSight™ LC-MS/MS

It is very well known that Black pepper is a complex matrix that requires a proper extraction and clean-up method for interferences. In this study, a fast, sensitive and selective multi-residue method has been developed for analysis of over 136 pesticides in Pepper samples by coupling a modified ...

PDF 1 MB
Method Validation for Atrazine Analysis in Fresh, Atypical Mineral and Carbonated Waters

EU water policies are reevaluated on a consistent basis to ensure water sources do not contain contaminants at levels above regulatory levels. As regulations are reviewed, regulatory limits are often lowered, and analytical techniques must adapt to meet the new stringent requirements.

In th ...

PDF 1 MB
Multi-residue Analysis of Pesticides in Animal Feed Using the QSight LC/MS/MS

Pesticides are employed in the growing of crops to prevent damage from a number of pests and fungi. When crops are grown to produce feed for livestock, there is a potential for pesticides residues to remain on the feeding stuffs, posing a risk to the livestock ingesting them. Pesticide residues ...

PDF 2 MB
Novel ESI and APCI LC/MS/MS Method for Testing Cannabis and Hemp Concentrate Samples

The use of cannabis concentrates and CBD products (edibles, topicals, vape products, etc.) has increased in popularity as new regulation has been passed legalizing medicinal and recreational use in a number of states and provinces. Testing to ensure that pesticide and mycotoxin levels in cannabis ...

PDF 1 MB
Rapid Determination of Trace Amounts of Aniline and Its Derivatives by Direct Injection UHPLC/MS/MS

Aniline and aniline derivatives are widely used as raw materials and intermediates in the polymer, rubber, dye, pesticide and pharmaceutical industries. Unintended releases of aniliane or its derivatives into the environment pose a serious threat, with release possible during any stage of product ...

PDF 587 KB
Simultaneous Detection of Estrogenic and Progestogenic Hormones in Edible Bird's Nest

This application note presents a sensitive and reliable LC/MS/MS method using the 爱游戏平台注册登录 QSight

PDF 859 KB
Simultaneous Determination of Pesticides Residues and Illegal Additives in Wine

Wine can often contain pesticides and fungicides that have been sprayed on the fruits during their growing period. In addition to these contaminants, wine can also contain additives that have been deliberately added during production processes to improve its flavor and color. In this study, a sim ...

PDF 1006 KB
Simultaneous Determination of Plant Growth Regulators in Bean Sprouts

A simple and sensitive method for the simultaneous determination of plant growth regulators

PDF 2 MB
“No Dilute” Just Shoot: Robustness of a QSight LC-ESI-MS/MS for Low Level Pesticide Residue Analysis in Wine

In this study, the QSight LC-MS/MS system was used to evaluate the potential of eliminating sample preparation for trace level pesticide analysis in a complex sample such as wine. We injected undiluted red and white wine samples into the mass spectrometer and studied reproducibility in analysis o ...

PDF 962 KB

Brochure

Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, ...

PDF 3 MB
QSight Pesticides Analyzer Brochure

Pesticides can adversely affect human health through the food we consume but can also leach into soil and groundwater and impact us through the environment. To keep up with a complex and constantly changing regulatory environment, your pesticide analysis solution needs to keep up with your burgeonin ...

PDF 9 MB
QSight Triple Quadrupole LC/MS/MS

Whether you’re a lab manager or a bench chemist, you know firsthand how things are changing quickly in food and environmental analysis. And your lab needs to change to keep pace.

PDF 8 MB

Poster

Infographic - Solutions for your Toxicology Lab

Infographic Poster showing the range of different analytical solutions for Toxicology Labs; from GC and LC, to ICP-MS and UV-Vis. Benchtop and floor standing chromatography, spectroscopy and thermal solutions for everyday robust and reliable analyses.

FOR RESEARCH USE ONLY. NOT FOR USE IN D ...

PDF 460 KB

Product Note

PDF 890 KB
QSight Simplicity 3Q Software Suite

Our modular Simplicity 3Q™ software is ideal for acquiring, quantifying and reporting

PDF 1 MB
QSight Triple Quadrupole LC/MS/MS Preparing Your Lab

Lab reequirements for QSight triple quad LC/MS/MS systems, including storage, suppleis, space, electrical, power, gas supply requirements

PDF 660 KB

Technical Note

Flow Characteristics of a Laminar Flow Interface for LC/MS/MS

Simulation using sophisticated modeling techniques has become a powerful tool for mass spectrometry

PDF 1 MB
Ion Transmission Through a Quadrupole Ion Guide

Ion Transmission Through a Quadrupole Ion Guide Under the Combined Influence of Viscous Flow and RF

PDF 1 MB
Theoretical Studies of Swirling Flow and Heating Methods

Theoretical Studies of Swirling Flow and Heating Methods on Droplet Evaporation in a Heated Coaxial

PDF 503 KB
Baidu