For high-throughput laboratories running single-element or sequential multi-element determinations using flame atomic absorption (AA) for many samples daily, looking for both total automation of standard and samples preparation as well as high-speed and accurate sample analysis without any user intervention.
false false
The FAST Flame 2 accessory is a combination of high-speed autosampler, two precision peristaltic pumps and a switching valve, providing quick sample turnaround with fast rinse-out, short signal stabilization times and no sample-to-sample memory effect. The FAST Flame 2 accessory rapidly fills a sample loop via vacuum and then switches to inject the sample loop while the autosampler moves to the next sample, removing the wait time associated with self-aspiration or peristaltic pumping and the long rinse-in and rinse-out times associated with autosampler movement and flushing resulting in sample-to-sample times as short as 15 seconds. Rapid injection and rinse-out result in a throughput of over 560 samples per hour—up to 40% higher than manual analysis for single-element determinations by Flame AA.
FAST Flame 2 provides the ability to mechanically pump the sample during injection, allows for ideal optimization of nebulizer and flame conditions, eliminates variability due to changes in sample viscosity, dissolved solids and tubing length and also provides long-term sample flow stability. Plus, FAST Flame 2 also provides in-line dilution, allowing the analyst to create a single intermediate standard and then the FAST Flame 2 accessory to automatically generate all calibration standards in-line, as required. In addition, FAST Flame 2 can be set to identify over-range samples and then utilize the in-line dilution capability to automatically re-run a sample that falls outside the calibration range at an increased dilution factor to bring the signal within the calibration and provide accurate measurement along with a passed QC check.
Accuracy of dilution is demonstrated by excellent linearity of the calibration curve (R2 > 0.9999). Sample dilution can be predefined on a per-sample basis, allowing for a wide range of dilution factors (1x-50x) to be used when sample types or elemental concentrations vary greatly. The total flow rate delivered by the two peristaltic pumps is constant, but the ratio of the two flows is automatically varied to dilute samples or to build a calibration curve by dilution of a single standard solution.
高度 | 15.0 cm |
---|---|
長度 | 34.0 cm |
便攜式 | No |
產品品牌名稱 | FAST Flame |
寬度 | 2.0 tray |
爱游戏平台注册登录 ’s FAST Flame Sample Automation Platform offers the lowest cost-per-element flame AA analysis on the market, delivering unparalleled speed, consistency and precision.
這項工作證明了通過火焰原子吸收法精確測量各種新鮮水果和幹果中的營養元素的能力,方法使用快速火焰自動取樣裝置實現了高通量分析。
這項工作展示了PinAAcle 900火焰原子吸收光譜儀測量葡萄酒中銅、鐵和錳的能力,符合中國葡萄酒進口法規,結合快速火焰樣品自動進樣器以提高分析通量。
這項工作證明了通過火焰原子吸收法精確測量各種牛奶類型中營養元素的能力,使用快速火焰樣品自動進樣器來實現高樣品通量分析。
這些營養強化早餐麥片的高效生產需要精心的配方和批次間的一致性。持續分析穀物中營養添加劑和總微量元素含量是食品生產商量化其穀物產品的質量和一致性的一種方法。快速、準確、方便地分析樣品的能力是及時報告數據、實時進行批量調整和增強連續過程控製的關鍵。食品生產商還必須符合營養標簽指南,該指南要求對微量元素進行準確評估,以符合標簽監管要求。
This work demonstrates the analysis of mineral elements in a variety of drinking waters using the PinAAcle 900 AA spectrometer coupled with a FAST Flame accessory.
Consumers select fruit juice because it is a tasty, convenient beverage and generally understood to be a more nutritious alternative to carbonated beverages. For 100% juice products, the nutrition content of the original fruit itself is well known, which translates to the expected nutritional val ...
One of the major challenges in the mining industry occurs early on the in the exploration phase, when determining where to dig. To establish if an area as viable, drilling and sample collection ensues at high volumes, necessitating rapid, accurate and repeatable analyses for minerals and metals o ...