The core of 爱游戏平台注册登录 ’s headspace is our patented pressure-balance technology that far surpasses valve and loop in performance when it comes to accuracy and repeatability. Pressure-balance provides rapid transfer of analytes to the GC without re-equilibration in a gas-sampling valve or syringe and minimizes loss of analytes. Injection amount is programmable by time or by volume without requiring any hardware change.
false falsePlease enter valid quantity
Please log in to add favorites.
NULL OR EMPTY CART
This mid-capacity automated headspace sampler includes a built-in trap to concentrate samples to increase system sensitivity. Standard 爱游戏平台注册登录 9mL or 22mL sample vials can be used and up to 40 vials can be loaded into the removable vial magazine for automated analysis. Overlapping thermostatting of up to 12 vials in Constant Mode for maximum productivity. An algorithm adjusts the virtual oven size for maximum throughput.
Programmable power-saving and gas-saving Economy Mode comes standard on all models. Automatic system and vial leak checks performed before analysis provide assurance of precision and sensitivity. All models with the built-in trap include programmable pneumatic control. A kit is available to offer safe use of hydrogen as a carrier gas. An optional frequency-scanning shaker is available to reduce equilibration time. Internal standard addition is available for trap models.
Height | 61.0 cm |
---|---|
Length | 34.0 cm |
Maximum Temperature | Oven Max Temp 210 °C |
Minimum Temperature | Oven Min Temp 35 °C |
Portable | No |
Product Brand Name | TurboMatrix |
Type | HS-40 Trap |
Volume | 40 vials |
Weight | 33.0 kg |
Width | 43.0 cm |
Butylated hydroxytoluene (BHT) is a common food additive used to protect foods from spoilage. Concern exists that long-term human consumption of BHT may have potential health risks. Analysis of BHT is needed for both food quality and safety reasons.
Trimethylamine (TMA) is a volatile organic compound known to be a major contributor to malodor pollution. Created in a gaseous form as a result of the manufacture, use and disposal of materials utilized in sewage treatment plants, the low odor threshold of TMA results in regular poor air quality ...
Ensuring the quality and consistency of coffee is vitally important, as it is one of the world’s most consumed beverages. The taste of a cup of coffee depends upon a number of factors, including the coffee bean utilized, as well as the roasting, grounding and brewing process. In this application ...
Although considered pharmacologically inert, pharmaceutical excipients have been shown to interact with active drug substances to affect the safety and efficacy of drug products.Therefore, there is an increasing awareness of the necessity to understanding interactions between excipients and the a ...
Bromoethane (EtBr) occurs both naturally and anthropogenically, and is widely used as a broad-spectrum pesticide in grain storage fumigation to prevent fungi and weed production, or control insect and rodent populations in storage facilities. Owing to potential health risks when inhaled or consum ...
Chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) are fully or partially halogenated paraffin hydrocarbons. CFCs, in the form of polyether polyol mixtures, have been widely used as blowing agents in the manufacture of rigid polyurethane foams (PU) used as insulation products. Owing ...
Thymopentin (TP5), a 5-amino-acid polypeptide, is a safe and effective immunostimulant utilized in the treatment of a variety of immune disorders. Several residual solvents are used in the manufacture of TP5, including the "universal solvent" N,N-dimethylformamide (DMF), known for its high solubi ...
Volatile organic compounds (VOCs) are a series of compounds with high vapor pressure and boiling points from 50 to 250 degrees centigrade. These characteristics lead to the tendency for large numbers of molecules to evaporate, or volatilize, from their solid state into the air. VOCs are present i ...
Epichlorohydrin, a raw material found in resins, can occur in drinking water at concentration which are hazardous to human health. The use of ephichlorohydrin is increasingly regulated. This article presents an analytical technique to determine the concentration of epichlorohydrin in the drinking ...
This application note demonstrates the use of a new sample-introduction technology incorporated in TurboMatrix HS-110 Trap for U.S. EPA Method 8260B for analysis, identification and quantification of volatile organic compounds (VOCs) that have boiling points below 200 °C.
Today’s plastics are some of the most used materials on a global volume basis. Broadly integrated into today’s industrial and commercial lifestyles, they make a major, irreplaceable contribution to virtually every product category.
In this compendium you will find a wide range of applicatio ...
Although considered pharmacologically inert, pharmaceutical excipients have been shown to interact with active drug substances to affect the safety and efficacy of drug products. One of the areas of major concern is the potential chemical interaction between impurities in the excipient and the dr ...
This application note describes the automated HS-GC/NPD technique applied to the analysis of various type of rice samples. This method was successful for the determination of a key aroma compound, 2AP, in rice sample with different varieties. The method showed in this study is rapid, convenient and ...
To meet the growing demand for personal protective equipment following the beginning of the COVID-19 pandemic, face mask production from existing and new manufacturers increased drastically. Testing masks to confirm they do not contain chemical residues, such as volatile organic compounds (VOCs) ...
ASTM International publishes a number of different methods for the determination of volatile compounds in water-based coatings. Method D3960 is a gravimetric technique where a sample of known weight is baked under specific conditions; the % weight of volatile organic compounds (VOCs) is calculated f ...
The development of methodology to measure VOCs at low levels using GC-MS coupled with Headspace Trap sample introduction is described here. The methodology is based on U.S. EPA Method 8260B.
Monitoring the consistency and quality in soft drinks is essential to ensure a positive brand image and a loyal customer base. Our full portfolio of chromatography solutions, including LC, GC and GC/MS, enables you to meet – and even exceed – your quality control goals with rapid, intuitive, and ...
Increasing demands for efficiency, productivity, data quality, and profitability pose ongoing challenges for lubricant testing labs, like yours. Whether you need to achieve quick turnaround times, minimize downtime, or maximize lab efficiencies, you can rely on 爱游戏平台注册登录 for a comprehensive set of ...
Headspace gas chromatography offers an efficient sample-preparation technique that can save both time and money in the analysis of VOCs in a number of matrices. Headspace sampling is a separation technique which allows for the extraction of headspace vapor from a sealed sample, with subsequent in ...
This field application report describes the use of a TurboMatrix™ HS-110 Trap and Clarus® 500 GC/MS optimized for low-level determination of fuel oxygenates by U.S. Environmental Protection Agency Method 8260B using the new headspace-trap technology.
Consumables reference guide for the TurboMatrix Headspace. TurboMatrix Headspace and high-sensitivity Headspace Trap samplers provide unparalleled precision and ease of use for numerous GC or GC/MS volatile-analysis applications. The system can manage up to 12 samples simultaneously, ensuring that t ...
This poster lays out our whole material characterization range for the analysis of polymers and plastics. Find ideal techniques and instruments at each stage in the polymer manufacturing process: Resin Development - Resin Manufacture - Compound Development - Compound Manufacture - Product Formi ...
Product Certificate for the TurboMatrix Headspace HS110/HS16/HS40