爱游戏平台注册登录

關於Revvity-- 以科技之能,突破人類潛能的邊界

(Revvity的前身是隸屬於爱游戏登录网 )


兩家獨立企業由此誕生

生命科學與診斷 & 分析和企業服務

check quantity

VIEWPLATE-384 TC, White, clear bottom, sterile TC treated, Case of 40

384-well tissue culture treated (TC-treated) sterile ViewPlate microplate with white well walls and a clear bottom for viewing plates under a microscope or bottom reading measurements.

貨號 6007480
Request Technical Support

請輸入有效數量

請登錄以添加收藏夾。

購物車為空

詳細信息

Our ViewPlate microplates are engineered for bottom reading systems. This high quality microplate can be utilized in your cell based assay for superior results.

Leveraging years of assay and instrument experience in plate detection, 爱游戏平台注册登录 designs better microplates for better performance that guarantees better results for all 爱游戏平台注册登录 applications.

Packaging Notes:

  • Cases of forty 384-well TC-treated plates are packaged as 4 sleeves of 10 plates each. Lids included.

Well Plate Dimensions

Well format: 384-well

Description Specification
Number of Rows 16
Number of Columns 24
Well volume 135 µL
Recommended working volume 25 µL- 125 µL
Height (mm) 14.4
Length (mm) 127.76
Width (mm) 85.48
Well diameter (mm) 3.3
Well depth (mm) 11.5
A1 to top offset (mm) 8.99
A1 to side offset (mm) 12.13
Well-to-well spacing (mm) 4.5

規格

自動化兼容 Yes
塗層處理 TC-treated, Sterile
顏色 White/Clear Bottom
檢測方法 Luminescence, Alpha, Time-Resolved Fluorescence (TRF & TR-FRET), Radiometric
Format Microplates
材料 Polystyrene
產品品牌名稱 ViewPlate
運輸條件 環境
Sterile Yes
產品尺寸 Case of 40
阱數量 384 well plate
資源
  • 所有

單頁

應用文獻

Measuring PD-L1 and PD-1 Expression in Human Cells with LANCE Ultra TR-FRET

Immuno-oncology is an exciting area within cancer research and among the most promising approaches to activating therapeutic antitumor immunity is through the blockade of immune checkpoints. The programmed cell death-1 (PD-1) immune checkpoint pathway is a negative regulator of T cell immune functio ...

PDF 4 MB
Measuring PD-L1 Expression in Breast Cancer Cell Lines with AlphaLISA

Too many candidates, too little time. The lack of robust, rapid, high-throughput assays to identify and qualify potential therapeutic targets in areas such as cancer research continues to cost valuable time. What if you could increase assay throughput without compromising sensitivity, obtain more da ...

PDF 4 MB

海報

Running an Aequorin Cell-Based Luminescent Assay on the FLIPR TETRA

We have shown here that signal intensity for the selected catalog aequorin cell lines is strong enough to allow its measurement by the non-luminescence dedicated FLIPR

PDF 270 KB
Baidu
map